Simple jQuery Dropdowns
Please use this identifier to cite or link to this item: http://repository.li.mahidol.ac.th/dspace/handle/123456789/12037
Title: Flow cytometric CD4 enumeration of four different HIV-infected blood samples at the cost of one monoclonal antibody reagent
Authors: Egarit Noulsri
Surada Lerdwana
Kasama Sukapirom
Charin Thepthai
Nattawat Onlamoon
Boonrat Tassaneetrithep
Kovit Pattanapanyasat
Mahidol University
Keywords: Immunology and Microbiology;Medicine
Issue Date: 1-Jun-2011
Citation: Asian Pacific Journal of Allergy and Immunology. Vol.29, No.2 (2011), 190-199
Abstract: Background: The frequency and absolute number of CD4 + T-lymphocytes continue to be one of the major clinical markers for management of HIV/AIDS. The present standard dual-platform (DP) three-color and two-color PanLeucogating flow cytometric (FCM) methods for most developing countries are either expensive if manufacturers' monoclonal antibody reagents are used or limited due to an insufficient supply of generic reagents. Clearly, more affordable FCM methods are needed. Objective: To develop a novel DP FCM method using biotin-streptavidin-fluorochrome labeling in combination with the two standard DP methods for 4 different white blood cells (WBC) using only one monoclonal antibody reagent. Methods: The percentage of CD4 + T-lymphocytes in 116 HIV-infected blood samples was determined using our new method. Results were compared with the two standard methods. Correlation and agreement of the pair method were determined using linear regression, Bland- Altman and percent similarity analysis. Results: Our study showed that percentage of CD4 + T-lymphocyte values obtained from the new method correlated highly with the standard three-color and the two-color methods (r 2 = 0.95 {n = 52} and 0.97 {n = 64}). The mean bias and percent similarity for the new method compared with the two standard methods were -0.53% (limit of agreement {LOA}:-5.22% to +4.16% with percent similarity of 99.28; and -0.22% with LOA of -3.42% to +2.98%, the percent similarity of 98.15, respectively. Conclusions: Our FCM method using biotin to label 4 different WBC samples followed by streptavidin staining is reliable for determination of CD4 + T-lymphocytes. Such an approach will significantly reduce the cost for monitoring HIVinfected patients in resource-limited settings.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79959432834&origin=inward
http://repository.li.mahidol.ac.th/dspace/handle/123456789/12037
ISSN: 22288694
0125877X
Appears in Collections:Scopus 2011-2015

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.