Title: Performance evaluation of the alere PIMA CD4 test for monitoring HIV-infected individuals in resource-constrained settings
Authors: Kasama Sukapirom
Nattawat Onlamoon
Charin Thepthai
Korakot Polsrila
Boonrat Tassaneetrithep
Kovit Pattanapanyasat
Mahidol University
Keywords: Medicine
Issue Date: 1-Oct-2011
Citation: Journal of Acquired Immune Deficiency Syndromes. Vol.58, No.2 (2011), 141-147
Abstract: Background: Enumeration of CD4+ T-lymphocytes is important in the management of HIV. However, standard laboratory systems based on flow cytometry are expensive, complicated, and thus unavailable to most resource-limited settings where a low-cost and fully automated point-of-care CD4 testing system is required. In attempts to address this issue, a study was conducted to validate the Alere PIMA point-of-care CD4 test. Method: Duplicate values of the absolute number of CD4+ T-lymphocytes in 203 HIV-infected blood samples obtained using the PIMA system were compared with the two predicate single-platform FACSCount and the dual-platform FACSCan (Becton Dickinson Biosciences). RESULTS:: The overall absolute CD4+ T-lymphocyte count obtained using the PIMA system correlated highly with the FACSCount (r 2 = 0.957; mean bias,-54.2 cells/μL; limit of agreement,-190.9 to +82.5 cells/μL) and the FACSCan (r 2 = 0.957; mean bias-44.0 cells/μL; limit of agreement,-179.7 to +91.6 cells/μL). Good correlation and low biases were also observed for samples with CD4+ T-lymphocyte count ranges of 0 to 200 and 0 to 350 cells/μL. Additionally, there was no significant difference in absolute CD4+ T-lymphocyte counts noted between the duplicate samples using the PIMA system. Conclusions: This new point-of-care product is a simple and reliable system and should contribute significantly to the simplification of performing CD4 testing and thus increase access for patients in resource-limited settings. The inability to obtain values for the frequency (%) of CD4+ T-lymphocyte count is one limitation of the PIMA system, the addition of which would be of value for clinical staging or monitoring in HIV-infected pediatric patients. © 2011 by Lippincott Williams & Wilkins.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=80052966207&origin=inward
http://repository.li.mahidol.ac.th/dspace/handle/123456789/12272
ISSN: 10779450
15254135
Appears in Collections:Scopus 2011-2015

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.