Title: Comparison of the region-based and pixel-wise methods for cardiac T2* analysis in 50 transfusion-dependent thai thalassemia patients
Authors: Pairash Saiviroonporn
Vip Viprakasit
Thananya Boonyasirinant
Archrob Khuhapinant
John C. Wood
Rungroj Krittayaphong
Faculty of Medicine, Siriraj Hospital, Mahidol University
Thalassemia Center
Division of Cardiology
Mahidol University
University of Southern California
Keywords: Medicine
Issue Date: 1-May-2011
Citation: Journal of Computer Assisted Tomography. Vol.35, No.3 (2011), 375-381
Abstract: Purpose: To compare the observer variability of the conventional region-based (RB) to the typical and proposed pixel-wise (PW) methods for cardiac T2* analysis in thalassemia patients. Design AND Methods: Fifty thalassemia major patients were enrolled for the study. Short-axis bright- and black-blood sequences were acquired and analyzed using the RB and PW methods. Regions were defined using the whole septum (WS) or partial septum (PS). From the same PS region, results were reported by mean (PS-PW) and median (MPS-PW). Intraobserver and interobserver variabilities were investigated on all data set by 2 independent observers blinded to the result. Results: The T2* values from the PS-PW and MPS-PW methods were comparable to the conventional WS-RB method on both scanning techniques. When comparing the interobserver variability from the WS-RB to the PS-PW method, the coefficient of variation of the PS-PW method was equivalent (4.5% vs 4.7%, P = NS) for the bright-blood technique but 31% lower (4.0% vs 2.8%, P = 0.21) for the black-blood technique. The proposed MPS-PW method performed even better with respect to the conventional WS-RB method, decreasing interobserver coefficient of variation by 24% (4.5% vs 3.5%, P = 0.08) and 42% (4.0% vs 2.4%, P = 0.02), respectively. Intraobserver reproducibility followed the same trend. Conclusions: The proposed PW method using the median of T2* values calculated from partial interventricular septum region provided lower intraobserver and interobserver variabilities compared with the conventional RB or typical PW methods. Copyright © 2011 by Lippincott Williams & Wilkins.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79957826792&origin=inward
http://repository.li.mahidol.ac.th/dspace/handle/123456789/12528
ISSN: 15323145
03638715
Appears in Collections:Scopus 2011-2015

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.