Simple jQuery Dropdowns
Please use this identifier to cite or link to this item: http://repository.li.mahidol.ac.th/dspace/handle/123456789/20285
Title: Low-tube-current multidetector CT for children with suspected extrinsic airway compression
Authors: Preeyacha Pacharn
Stacy A. Poe
Lane F. Donnelly
Cincinnati Children's Hospital Medical Center
Mahidol University
Keywords: Medicine
Issue Date: 1-Dec-2002
Citation: American Journal of Roentgenology. Vol.179, No.6 (2002), 1523-1527
Abstract: OBJECTIVE. The purpose of our study was to review the technical success achieved using low-tube-current multidetector CT for the evaluation of children with suspected extrinsic airway compression and to evaluate the need for sedation during this procedure. MATERIALS AND METHODS. We reviewed all CT examinations performed for the evaluation of extrinsic airway compression during the first year after installation of a multidetector CT scanner at a pediatric hospital. We recorded the technical parameters including tube current, kilovoltage, slice thickness, mode of study, sedation technique, and amount of contrast material and noted which postprocessing techniques were applied. Studies were evaluated for timing of contrast bolus, image quality, motion artifact, need for sedation, and the diagnoses made. RESULTS. Fifty-four studies were performed in 50 patients (30 boys, 20 girls; age range, 15 days to 17 years; mean age, 2.4 years). The mean tube current was 52.2 mA (range, 30-140 mA). Thirty-four studies (63%) were performed without sedation: 12 with sedation administered under supervision of the radiologist, six with general anesthesia supervised by an anesthesiologist, and two in patients who arrived in the radiology department already intubated. Imaging quality was excellent in 35 studies (65%), diagnostic in 19 studies (35%), and poor in none. Motion artifact was present on several slices in two examinations (4%). Contrast medium administration was well-timed in 49 studies (91%), early in three studies (5%), and late in two studies (4%). Airway abnormalities were detected in 26 (48%) of the studies and included extrinsic compression by vascular anomalies (n = 14) or nonvascular masses (n = 5) and intrinsic airway disease without extrinsic compression (n = 7). CONCLUSION. Evaluation for extrinsic compression of the airway in children can be accomplished using a low-tube-current multidetector CT protocol; in most pediatric patients, the examination can be performed without sedation.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0036891767&origin=inward
http://repository.li.mahidol.ac.th/dspace/handle/123456789/20285
ISSN: 0361803X
Appears in Collections:Scopus 2001-2005

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.