Simple jQuery Dropdowns
Please use this identifier to cite or link to this item: http://repository.li.mahidol.ac.th/dspace/handle/123456789/23245
Title: Development of a simple extraction cell with bi-directional continuous flow coupled on-line to ICP-MS for assessment of elemental associations in solid samples
Authors: Janya Buanuam
Kasipa Tiptanasup
Juwadee Shiowatana
Manuel Miró
Elo Harald Hansen
Mahidol University
Universitat de les Illes Balears
Danmarks Tekniske Universitet
Keywords: Environmental Science;Medicine
Issue Date: 7-Dec-2006
Citation: Journal of Environmental Monitoring. Vol.8, No.12 (2006), 1248-1254
Abstract: A continuous-flow system comprising a novel, custom-built extraction module and hyphenated with inductively coupled plasma-mass spectrometric (ICP-MS) detection is proposed for assessing metal mobilities and geochemical associations in soil compartments as based on using the three step BCR (now the Measurements and Testing Programme of the European Commission) sequential extraction scheme. Employing a peristaltic pump as liquid driver, alternate directional flows of the extractants are used to overcome compression of the solid particles within the extraction unit to ensure a steady partitioning flow rate and thus to maintain constant operationally defined extraction conditions. The proposed flow set-up is proven to allow for trouble-free handling of soil samples up to 1 g and flow rates ≤10 mL min-1. The miniaturized extraction system was coupled to ICP-MS through a flow injection interface in order to discretely introduce appropriate extract volumes to the detector at a given time and with a given dilution factor. The proposed hyphenated method demonstrates excellent performance for on-line monitoring of major and trace elements (Ca, Mn, Fe, Ni, Pb, Zn and Cd) released when applying the various extracting reagents as addressed in the BCR scheme, that is, 0.11 M CH 3COOH, 0.1 NH2OH·HCl and 30% H2O 2, even when a well recognized matrix-sensitive detector, such as ICP-MS, is used. As a result of the enhanced temporal resolution of the ongoing extraction, insights into the breaking down of phases and into the kinetics of the metal release are obtained. With the simultaneous multielement detection capability of ICP-MS, the dynamic fractionation system presents itself as an efficient front-end for evaluation of actual elemental association by interelement comparison of metals leached concurrently during the extraction time. Thus, the intimate elemental association between Cd and Zn in contaminated soils could be assessed. © The Royal Society of Chemistry 2006.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33751580130&origin=inward
http://repository.li.mahidol.ac.th/dspace/handle/123456789/23245
ISSN: 14640325
Appears in Collections:Scopus 2006-2010

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.