Simple jQuery Dropdowns
Please use this identifier to cite or link to this item: http://repository.li.mahidol.ac.th/dspace/handle/123456789/27253
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWansadaj Jaroenramen_US
dc.contributor.authorWansika Kiatpathomchaien_US
dc.contributor.authorTimothy W. Flegelen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherThailand National Center for Genetic Engineering and Biotechnologyen_US
dc.date.accessioned2018-09-13T06:25:44Z-
dc.date.available2018-09-13T06:25:44Z-
dc.date.issued2009-04-01en_US
dc.identifier.citationMolecular and Cellular Probes. Vol.23, No.2 (2009), 65-70en_US
dc.identifier.issn08908508en_US
dc.identifier.other2-s2.0-61449161963en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=61449161963&origin=inwarden_US
dc.identifier.urihttp://repository.li.mahidol.ac.th/dspace/handle/123456789/27253-
dc.description.abstractLoop-mediated isothermal amplification (LAMP) allows rapid amplification of nucleic acids under isothermal conditions using a set of four specifically designed primers that recognize six distinct target sequences. It can be combined with a chromatographic lateral flow dipstick (LFD) for highly specific, rapid and simple visual detection of WSSV-specific amplicons. Using this protocol, a 30-min amplification followed by 5 min hybridization with an FITC-labeled DNA probe and 5 min LFD resulted in visualization of DNA amplicons trapped at the LFD test line. Thus, 10 min for rapid DNA extraction followed by LAMP combined with LFD detection resulted in a total assay time of approximately 50 min. Detection sensitivity was comparable to other commonly-used methods for nested PCR detection of WSSV but had the additional advantages of reduced assay time, confirmation of amplicon identity by hybridization and elimination of electrophoresis with carcinogenic ethidium bromide. © 2008 Elsevier Ltd. All rights reserved.en_US
dc.rightsMahidol Universityen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=61449161963&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.titleRapid and sensitive detection of white spot syndrome virus by loop-mediated isothermal amplification combined with a lateral flow dipsticken_US
dc.typeReviewen_US
dc.rights.holderSCOPUSen_US
dc.identifier.doi10.1016/j.mcp.2008.12.003en_US
Appears in Collections:Scopus 2006-2010

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.