Please use this identifier to cite or link to this item:
http://repository.li.mahidol.ac.th/dspace/handle/123456789/27270
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | K. Paisooksantivatana | en_US |
dc.contributor.author | A. Kongsomgan | en_US |
dc.contributor.author | W. Banyatsuppasin | en_US |
dc.contributor.author | K. Khupulsup | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.date.accessioned | 2018-09-13T06:26:19Z | - |
dc.date.available | 2018-09-13T06:26:19Z | - |
dc.date.issued | 2009-03-01 | en_US |
dc.identifier.citation | Diabetes Research and Clinical Practice. Vol.83, No.3 (2009) | en_US |
dc.identifier.issn | 01688227 | en_US |
dc.identifier.other | 2-s2.0-59349120951 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=59349120951&origin=inward | en_US |
dc.identifier.uri | http://repository.li.mahidol.ac.th/dspace/handle/123456789/27270 | - |
dc.description.abstract | Background: Many assays used for HbA1c measurement can be interfered by hemoglobin variants. Hemoglobin E is one of the most common variant. Effect of HbE on high performance liquid chromatography was widely reported but not on immunoassay. Objective: To determine the effect of hemoglobin E on HbA1c values by immunoassay methods. Material and methods: Two immunoassays were used for measurement of HbA1c in samples with hemoglobin type as A2A (normal controls, n = 60), EA (heterozygous hemoglobin E, n = 151), and EE (homozygous hemoglobin E, n = 43). Results within each assay and each hemoglobin typing group were compared. Mann-Whitney U test, Pearson's correlation and linear regression analysis were used. Results: There were significant differences of HbA1c values between normal controls and hemoglobin E-contained samples. Correlation between two assays was worse in the presence of hemoglobin E comparing to normal controls. Conclusion: Hemoglobin E can affect the immunoassays used for HbA1c measurement. Further studies are needed to understand the mechanism of interference. © 2008 Elsevier Ireland Ltd. All rights reserved. | en_US |
dc.rights | Mahidol University | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=59349120951&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Medicine | en_US |
dc.title | Influence of hemoglobin E on measurement of hemoglobin A1c by immunoassays | en_US |
dc.type | Letter | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.identifier.doi | 10.1016/j.diabres.2008.11.021 | en_US |
Appears in Collections: | Scopus 2006-2010 |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.