Simple jQuery Dropdowns
Please use this identifier to cite or link to this item: http://repository.li.mahidol.ac.th/dspace/handle/123456789/33601
Title: An automated in-chip-catalytic-spectrophotometric method for determination of copper(ii) using a multisyringe flow injection analysis-multipumping flow system
Authors: Piyawan Phansi
Camelia Henríquez
Edwin Palacio
Duangjai Nacapricha
Víctor Cerdà
Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs.
Mahidol University
Universitat de les Illes Balears
Keywords: Chemical Engineering;Chemistry;Engineering
Issue Date: 1-Jan-2014
Citation: Analytical Methods. Vol.6, No.21 (2014), 8494-8504
Abstract: © the Partner Organisations 2014. In this work a fully automated catalytic-spectrophotometric method for determination of copper at trace levels using a multisyringe flow injection system (MSFIA) and a multipumping flow system (MPFS) coupled to a micro-chip (Chip-MSFIA-MPFS) is presented. The reaction is based on the catalytic effect of Cu(ii) on the oxidation of the in situ reduced form of 2,6-dichlorophenolindophenol (DCPI)r, by hydrogen peroxide. Due to the importance of the mixing order of the reagents, a new design of the chip is proposed. DCPI, ascorbic acid and buffer are first propelled to mix in the front section of the chip using MPFS. Then this reagent mixture, together with hydrogen peroxide and the sample, is simultaneously dispensed to the rear section of the chip by using a multisyringe for mixing, heating and absorbance measurement of the product at 600 nm. The optimum conditions are 0.9 mmol L-1 DCPI, 3.6 mmol L-1 ascorbic acid, 0.8 mol L-1 ammonium chloride buffer, pH 10.5, and 0.3 mol L-1 H2O2. The proposed system is simple, rapid, selective and sensitive. We can determine trace levels of Cu(ii) at room temperature (25 °C). The main analytical characteristics of the proposed method are a detection limit of 0.12 μg L-1 of Cu(ii), a working range of 0.4-35.0 μg L-1 of Cu(ii), and a relative standard deviation of 0.79% (10 μg L-1 Cu(ii), n = 15). The system was successfully applied to water samples, certified reference materials (CRMs) of river and waste water, acid digested multivitamins and animal tissues with a sample throughput of 31 injections h-1. This journal is
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84908012833&origin=inward
http://repository.li.mahidol.ac.th/dspace/handle/123456789/33601
ISSN: 17599679
17599660
Appears in Collections:Scopus 2011-2015

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.