Please use this identifier to cite or link to this item: http://repository.li.mahidol.ac.th/dspace/handle/123456789/35862
Title: Monomer elution in relation to degree of conversion for different types of composite
Authors: Pong Pongprueksa
Jan De Munck
Radu Corneliu Duca
Katrien Poels
Adrian Covaci
Peter Hoet
Lode Godderis
Bart Van Meerbeek
Kirsten L. Van Landuyt
KU Leuven– University Hospital Leuven
Mahidol University
KU Leuven
Universiteit Antwerpen
Keywords: Dentistry
Issue Date: 1-Dec-2015
Citation: Journal of Dentistry. Vol.43, No.12 (2015), 1448-1455
Abstract: © 2015 Elsevier Ltd. Objectives The aim of this study was to determine the degree of conversion (DC) and the monomer release of three composite types when employed following a layer- and bulk-filling technique. Methods The release of monomers from a 'conventional paste-like' (Filtek Z250), a 'conventional flowable' (Filtek Supreme XTE Flowable) and a 'bulk-fill' flowable composite (Filtek Bulk Fill Flowable) from the same manufacturer (3M ESPE, Seefeld, Germany) was determined. Ten cylindrical specimens per composite were built, either in two 2-mm layers or in one 4-mm bulk. DC was measured at the specimen top and bottom surface using micro-Raman spectroscopy, after which the specimens were immersed in 2 ml absolute ethanol for 24 h at 37 °C. This solution was refreshed weekly during six weeks and the concentration of BisGMA, BisEMA(6), BisPMA, UDMA, TEGDMA and BPA was determined by liquid chromatography/mass spectroscopy. Results DC at the specimen top and bottom was similar except for the bulk-fill technique, which resulted in significantly lower DC at the specimen bottom. The release of BisGMA and TEGDMA was initially very high, but rapidly dropped in the second week. In contrast, the release of BisPMA and UDMA increased initially, but then declined towards the sixth week. BisEMA(6) release was relatively steady over time. All composites released small amounts of BPA. The total monomer release was significantly lower for the layer- than the bulk-filling technique. Conclusions The slightly reduced degree of conversion at 4-mm depth resulted in a higher monomer elution when the composite was applied following a bulk-fill application method. Clinical significance Applying a flowable and a bulk-fill composite following a bulk-fill application method resulted in a significantly reduced degree of conversion at the bottom of polymerized composite specimens when compared to a layer-application method. This reduced polymerization degree was reflected in significantly increased monomer release.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84951299804&origin=inward
http://repository.li.mahidol.ac.th/dspace/handle/123456789/35862
ISSN: 03005712
Appears in Collections:Scopus 2011-2015

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.