Simple jQuery Dropdowns
Please use this identifier to cite or link to this item: http://repository.li.mahidol.ac.th/dspace/handle/123456789/36242
Title: Increased speed and image quality in single-shot fast spin echo imaging via variable refocusing flip angles
Authors: Andreas M. Loening
Manojkumar Saranathan
Nichanan Ruangwattanapaisarn
Daniel V. Litwiller
Ann Shimakawa
Shreyas S. Vasanawala
Stanford University School of Medicine
Mahidol University
GE Healthcare, United States
Keywords: Medicine
Issue Date: 1-Dec-2015
Citation: Journal of Magnetic Resonance Imaging. Vol.42, No.6 (2015), 1747-1758
Abstract: © 2015 Wiley Periodicals, Inc. Purpose To develop and validate clinically a single-shot fast spin echo (SSFSE) sequence utilizing variable flip angle refocusing pulses to shorten acquisition times via reductions in specific absorption rate (SAR) and improve image quality. Materials and Methods A variable refocusing flip angle SSFSE sequence (vrfSSFSE) was designed and implemented, with simulations and volunteer scans performed to determine suitable flip angle modulation parameters. With Institutional Review Board (IRB) approval/informed consent, patients referred for 3T abdominal magnetic resonance imaging (MRI) were scanned with conventional SSFSE and either half-Fourier (n = 25) or full-Fourier vrfSSFSE (n = 50). Two blinded radiologists semiquantitatively scored images on a scale from -2 to 2 for contrast, noise, sharpness, artifacts, cardiac motion-related signal loss, and the ability to evaluate the pancreas and kidneys. Results vrfSSFSE demonstrated significantly increased speed (â142-fold, P < 0.0001). Significant improvements in image quality parameters with full-Fourier vrfSSFSE included increased contrast, sharpness, and visualization of pancreatic and renal structures with higher bandwidth technique (mean scores 0.37, 0.83, 0.62, and 0.31, respectively, P ≤ 0.001), and decreased image noise and improved visualization of renal structures when used with an equal bandwidth technique (mean scores 0.96 and 0.35, respectively, P < 0.001). Increased cardiac motion-related signal loss with full-Fourier vrfSSFSE was seen in the pancreas but not the kidney. Conclusion vrfSSFSE increases speed at 3T over conventional SSFSE via reduced SAR, and when combined with full-Fourier acquisition can improve image quality, although with some increased sensitivity to cardiac motion-related signal loss.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84955754154&origin=inward
http://repository.li.mahidol.ac.th/dspace/handle/123456789/36242
ISSN: 15222586
10531807
Appears in Collections:Scopus 2011-2015

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.