Simple jQuery Dropdowns
Please use this identifier to cite or link to this item: http://repository.li.mahidol.ac.th/dspace/handle/123456789/42982
Title: Chromatic analysis by monitoring unmodified silver nanoparticles reduction on double layer microfluidic paper-based analytical devices for selective and sensitive determination of mercury(II)
Authors: Rattapol Meelapsom
Purim Jarujamrus
Maliwan Amatatongchai
Sanoe Chairam
Chadin Kulsing
Wei Shen
Ubon Rajathanee University
Mahidol University
Monash University
Keywords: Biochemistry, Genetics and Molecular Biology;Chemistry
Issue Date: 1-Aug-2016
Citation: Talanta. Vol.155, (2016), 193-201
Abstract: © 2016 Elsevier B.V. All rights reserved. This study demonstrates chromatic analysis based on a simple red green blue (RGB) color model for sensitive and selective determination of mercury(II). The analysis was performed by monitoring the color change of a microfluidic Paper-based Analytical Device (μPAD). The device was fabricated by using alkyl ketene dimer (AKD)-inkjet printing and doped with unmodified silver nanoparticles (AgNPs) which were disintegrated when being exposed to mercury(II). The color intensity was detected by using an apparatus consisting of a digital camera and a homemade light box generating constant light intensity. A progressive increase in color intensity of the tested area on the μPAD (3.0 mm) was observed with increasing mercury(II) concentration. The developed system enabled quantification of mercury(II) at low concentration with the detection limit of 0.001 mg L-1 (3 SD blank/slope of the calibration curve) and small sample volume uptake (2 μL). The linearity range of the calibration curve in this technique was demonstrated from 0.05 to 7 mg L-1 (r2=0.998) with good precision (RSD less than 4.1%). Greater selectivity towards mercury(II) compared with potential interference ions was also observed. Furthermore, the percentage recoveries of spiked water samples were in an acceptable range which was in agreement with the values obtained from the conventional method utilizing cold vapor atomic absorption spectrometer (CVAAS). The proposed technique allows a rapid, simple, sensitive and selective analysis of trace mercury(II) in water samples.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84964869857&origin=inward
http://repository.li.mahidol.ac.th/dspace/handle/123456789/42982
ISSN: 00399140
Appears in Collections:Scopus 2016-2017

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.