Simple jQuery Dropdowns
Please use this identifier to cite or link to this item: http://repository.li.mahidol.ac.th/dspace/handle/123456789/73840
Title: Inanimate surface contamination of SARS-CoV-2 during midfacial fracture repair in asymptomatic COVID-19 patients
Authors: Poramate Pitak-Arnnop
Nattapong Sirintawat
Chatpong Tangmanee
Passanesh Sukphopetch
Jean Paul Meningaud
Andreas Neff
Chulalongkorn Business School
Faculty of Tropical Medicine, Mahidol University
Mahidol University, Faculty of Dentistry
Hôpital Henri Mondor
Universitätsklinikum Gießen und Marburg, Standort Marburg
Keywords: Dentistry;Medicine
Issue Date: 1-Jan-2022
Citation: Journal of Stomatology, Oral and Maxillofacial Surgery. (2022)
Abstract: Purposes: To evaluate inanimate surface contamination of SARS-CoV-2 during midfacial fracture repair (MFR) and to identify relevant aggregating factors. Methods: Using a prospective non-randomised comparative study design, we enrolled a cohort of asymptomatic COVID-19 patients undergoing MFR. The predictor variables were osteofixation system (conventional titanium plates [CTiP] vs. ultrasound-assisted resorbable plates [USaRP]). The main outcomes were the presence of SARS-CoV-2 on four different surfaces. Other study variables were categorised into demographic, anatomical, and operative. Descriptive, bi- and multivariate statistics were computed. Results: The sample consisted of 11 patients (27.3% females, 63.6% right side, 72.7% displaced fractures) with a mean age of 52.7 ± 20.1 years (range, 19–85). Viral spread was, on average, 1.9 ± 0.4 m. from the operative field, including most oral and orbital retractors’ tips (81.8% and 72.7%) and no virus was found at 3 m from the operative field, but no significant difference was found between 2 osteofixation types. On binary adjustments, significantly broader contamination was linked to centrolateral MFR (P = 0.034; 95% confidence interval [CI], 0.05 to 1.02), and displaced MFR > 45 min (P = 0.022; 95% CI, 0.1 to 1.03). Conclusions: USaRP, albeit presumably heavily aerosol-producing, cause similar SARS-CoV-2 distribution to CTiP. Non-surgical operating room (OR) staff should stay ≥ 3 m from the operative field, if the patient is SARS-CoV-2-positive. Enoral and orbital instruments are a potential virus source, especially during displaced MFR > 45 min and/or centrolateral MFR, emphasising an importance of appropriate patient screening and OR organisation.
URI: http://repository.li.mahidol.ac.th/dspace/handle/123456789/73840
metadata.dc.identifier.url: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85123347603&origin=inward
ISSN: 24687855
Appears in Collections:Scopus 2022

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.