Browsing by Author "T. Yamsa-Ard"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Publication Metadata only Development of a novel classification and calculation algorithm for physical activity monitoring and its application(2014-02-12) J. Arnin; D. Anopas; P. Triponyuwasin; T. Yamsa-Ard; Y. Wongsawat; Mahidol University© 2014 Asia-Pacific Signal and Information Processing Ass. Exercise is a good alternative approach to be healthy. However, it can cause a body in negative outcome for people who over workout without proper manner. Therefore, the objective of this project is to develop an activity tracker called 'Feelfit' that has a high accuracy to measure levels of activity (with 5 intensities of exercises). Besides, challenging and motivating the exercise via feedback of detailed information such as burned calorie, activity percentage, and so on are proposed. An accelerometer, high accuracy tri-axial accelerometer (MMA8452Q), sends a value of acceleration in 3 axes acquired from body movement and then be processed and calculated physical activity behavior on a low-power microcontroller. This project has proposed a novel algorithm of physical activity classification and calories burned calculation. The algorithms were examined the accurateness by 10 healthy subjects (5 males and 5 females) aged 15-25 years old. The proposed algorithms were also compared with a commercial activity monitoring device; the accuracy of calories burned calculation is more than 80% and more than 90% for activity classification.Publication Metadata only The relationship between EEG and binaural beat stimulation in meditation(2015-01-01) T. Yamsa-Ard; Y. Wongsawat; Mahidol University© 2014 IEEE. The difficulty to understand meditation is the lack of exact methodology, replication of mind condition and depends on individual meditative practice. From these reasons, this research focuses on a relationship between meditation and EEG. The Quantitative EEG will be analyzed and observed in absolute power of each EEG rhythm. Coherence was also analyzed after participants practice meditation during binaural beat stimulation in both eyes-closed and opened four beat frequencies were selected, 5 Hz, 8Hz, 12Hz, and 18Hz respectively. The binaural beat stimulation will be classified into two groups which are pure beat and meta-music that combined binaural beat with other music. The result demonstrates that coherence is the significant index that shown the relationship between EEG and meditation. Theta and lower alpha absolute power also show the significant relationship which increase at frontal-midline. This research demonstrates that, coherence and absolute power are indices which can explain a meditation practice during binaural beat stimulation.Publication Metadata only Wireless-based portable EEG-EOG monitoring for real time drowsiness detection(2013-10-31) J. Arnin; D. Anopas; M. Horapong; P. Triponyuwasi; T. Yamsa-Ard; S. Iampetch; Y. Wongsawat; Mahidol UniversityDrowsiness is one of the major risk factors causing accidents that result in a large number of damage. Drivers and industrial workers probably have a large effect on several mishaps occurring from drowsiness. Therefore, advanced technology to reduce these accidental rates is a very challenging problem. Nowadays, there have been many drowsiness detectors using electroencephalogram (EEG), however, the cost is still high and the use of this is uncomfortable in long-term monitoring because most of them require wiring and conventional wet electrodes. The purpose of this paper is to develop a portable wireless device that can automatically detect the drowsiness in real time by using the EEG and electrooculogram (EOG). The silver (Ag) conducting fabric consolidated in a headband used as dry electrodes can acquire signal from the user's forehead. The signal was sent via the wireless communication of XBee® 802.15.4 to a standalone microcontroller to analyze drowsiness using the proposed algorithm. The alarm will ring when the drowsiness occurs. Besides, the automatic drowsiness detection and alarm device yields the real-time detection accuracy of approximately 81%. © 2013 IEEE.
