Clinical implications of an additional mediolateral implant option for a primary total knee system in an ethnically diverse population: 5-year interim results from a prospective, multicenter cohort study
item.page.dc.date.issued
2026-12-01
item.page.dc.type
item.page.dc.identifier.issn
09680160
item.page.dc.identifier.eissn
18735800
item.page.dc.identifier.doi
item.page.dc.identifier.scopus
2-s2.0-105050456093
item.page.dc.identifier.pmid
42743765
item.page.oaire.citation.title
Knee
item.page.oaire.citation.volume
63
item.page.dc.rights.holder
SCOPUS
item.page.dc.identifier.citation
Knee Vol.63 (2026)
punsarn.item.page.citation
Tang Q., Violante B., McLennan-Smith R., Park K.K., Charoencholvanich K. Clinical implications of an additional mediolateral implant option for a primary total knee system in an ethnically diverse population: 5-year interim results from a prospective, multicenter cohort study. Knee Vol.63 (2026). doi:10.1016/j.knee.2026.104638 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/119104
item.page.dc.title
Clinical implications of an additional mediolateral implant option for a primary total knee system in an ethnically diverse population: 5-year interim results from a prospective, multicenter cohort study
item.page.dc.contributor.author
item.page.oairecerif.author.affiliation
item.page.dc.contributor.correspondence
item.page.dc.contributor.other
item.page.dc.description.abstract
Background: Femoral component overhang can cause complications following primary total knee arthroplasty (TKA) and occurs more frequently in non-Caucasian populations due to anatomical differences insufficiently addressed by contemporary implants. The ANTHEM™ posterior-stabilized (PS) TKA system was designed to improve anatomical compatibility and reduce overhang. This prospective cohort study investigated implant survivorship, overhang frequency, and its clinical impact in Asian/Caucasian patients. Five-year interim results are reported. Methods: 148 knees (120 patients; mean age 67.1 years; 77.5% female; 50% Asian, 50% Caucasian) underwent primary TKA for osteoarthritis at 6 international centers. Follow-up occurred at 6 weeks, 1, 2, and 5 years. Primary outcome was implant survivorship. Secondary outcomes included KOOS, 2011 KSS, EQ-VAS, EQ-5D3L, and radiographic assessments. Femoral component fit and safety events were collected. Results: At 5 years, Kaplan–Meier survivorship estimates were 98.88% (95% CI: 92.29–99.84) for standard femorals and 96.88% (95% CI: 79.81–99.55) for narrow femorals. Six serious adverse device effects were reported − two possibly/directly related to the device/procedure. Radiographs showed 1 periprosthetic fracture and 5 non-progressive radiolucencies. No migration, loosening, osteolysis, or heterotopic ossification was observed. Overhang occurred in 12.8% of knees. All patient-reported outcomes improved significantly (p < 0.0001). Conclusion: This knee system demonstrated excellent survivorship, strong clinical performance, minimal complications, and low overhang rates across diverse populations, supporting the value of enhanced anatomical fit in achieving optimal TKA outcomes.
