Shear strengthening of reinforced concrete beams using alkali-treated abaca FRP: experimental behavior, code validation, and sustainability assessment
item.page.dc.date.issued
2026-06-01
item.page.dc.type
item.page.dc.identifier.issn
22875301
item.page.dc.identifier.eissn
2287531X
item.page.dc.identifier.doi
item.page.dc.identifier.scopus
2-s2.0-105045549381
item.page.oaire.citation.title
Advances in Concrete Construction
item.page.oaire.citation.volume
21
item.page.oaire.citation.issue
6
item.page.oaire.citation.startPage
771
item.page.oaire.citation.endPage
805
item.page.dc.rights.holder
SCOPUS
item.page.dc.identifier.citation
Advances in Concrete Construction Vol.21 No.6 (2026) , 771-805
punsarn.item.page.citation
Fakhruddin, Djamaluddin R., Irmawaty R., Ngeljaratan L.N., Limpaninlachat P. Shear strengthening of reinforced concrete beams using alkali-treated abaca FRP: experimental behavior, code validation, and sustainability assessment. Advances in Concrete Construction Vol.21 No.6 (2026) , 771-805. 805. doi:10.12989/acc.2026.21.6.771 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/118356
item.page.dc.title
Shear strengthening of reinforced concrete beams using alkali-treated abaca FRP: experimental behavior, code validation, and sustainability assessment
item.page.dc.contributor.author
item.page.oairecerif.author.affiliation
item.page.dc.contributor.correspondence
item.page.dc.contributor.other
item.page.dc.description.abstract
This study investigates the structural performance and sustainability of alkali-treated abaca fiber reinforced polymer (AbFRP) laminates as a low-carbon alternative to glass FRP (GFRP) for shear strengthening of reinforced concrete (RC) beams. Six RC beams (150×300×2300 mm, a/d=2.6) were tested under four-point bending: two controls, two GFRP-strengthened, and two AbFRP-strengthened in full U-wrap configuration. AbFRP laminates achieved tensile strength of 83.85 MPa and elastic modulus of 5027.1 MPa, with coefficients of variation below 8%. Both systems enhanced structural performance: ultimate load increased by 34.2% (GFRP) and 35.7% (AbFRP), with failure mode shifting from brittle shear to ductile flexure. Ductility index improved from 1.3 to 3.4 (GFRP) and 2.8 (AbFRP). Unlike GFRP, AbFRP exhibited pseudo-ductile strain hardening through progressive fiber rupture and fiber-matrix interfacial heterogeneity, producing a higher ultimate FRP strain (6384 με vs. 950 με) and enhanced energy dissipation. Theoretical validation against ACI 440.2R-17 confirmed that the bond-controlled strain limit (εfrp=0.004) yields conservative predictions, while using the measured rupture strain (εfu=0.017) overestimated shear capacity by 204%, confirming bond-controlled effective strain governs design. Cradle-to-gate assessment showed AbFRP reduced embodied energy by 63-85%, CO<inf>2</inf> emissions by 88%, and material cost by 71% relative to GFRP. These findings establish AbFRP as a structurally reliable, code-compatible, and environmentally efficient alternative for RC shear strengthening.
