A Dual-Path IoT Sensing and Communication Framework for Smart Building and Construction-Site Structural Monitoring
1
item.page.dc.date.issued
2026-09-01
item.page.dc.type
item.page.dc.identifier.eissn
20799292
item.page.dc.identifier.doi
item.page.dc.identifier.scopus
2-s2.0-105051838098
item.page.oaire.citation.title
Electronics Switzerland
item.page.oaire.citation.volume
15
item.page.oaire.citation.issue
18
item.page.dc.rights.holder
SCOPUS
item.page.dc.identifier.citation
Electronics Switzerland Vol.15 No.18 (2026)
punsarn.item.page.citation
Chen C.H., Hsu Y.H., Lee W.L., Wong H.K., Wu E.H.K., Yeh S.C., Thaipisutikul T. A Dual-Path IoT Sensing and Communication Framework for Smart Building and Construction-Site Structural Monitoring. Electronics Switzerland Vol.15 No.18 (2026). doi:10.3390/electronics15184118 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/119406
item.page.dc.title
A Dual-Path IoT Sensing and Communication Framework for Smart Building and Construction-Site Structural Monitoring
item.page.oairecerif.author.affiliation
item.page.dc.contributor.correspondence
item.page.dc.contributor.other
item.page.dc.description.abstract
Reliable structural monitoring for smart buildings and construction sites requires more than sensor acquisition; it requires sensing and communication paths that remain traceable, recoverable, and compatible with platform-side data processing under heterogeneous field constraints. This study presents a dual-path IoT sensing and communication framework that deliberately separates high-data-rate vibration monitoring from low-data-rate inclination-status monitoring while maintaining common requirements for preservation of available time information, data-source identification, and backend interpretability. The smart-building path integrates an ADXL355 triaxial accelerometer, ESP32-S3, Power over Ethernet (PoE), and Message Queuing Telemetry Transport (MQTT) for 200 Hz vibration acquisition, together with a second-order 10 Hz low-pass filter, 40-record batching, and a Flash LittleFS-based store-and-recovery mechanism that interleaves live and replayed records after reconnection. The construction-site path combines an SCL3300-D01 inclinometer with LoRaWAN, baseline-referenced relative-angle estimation, and a hysteresis state machine with distinct alarm and recovery thresholds. In a 24 h validation, four vibration nodes delivered all 69,120,000 expected records, and four forced-outage trials recovered all offline records while live transmission continued. Frequency-domain analysis confirmed attenuation of high-frequency components while retaining the dominant low-frequency response. The inclination path demonstrated quantifiable angle accuracy, correct alarm/recovery transitions, continuous LoRaWAN frame delivery over the observed interval, and correct backend decoding. The results show that path-specific communication design, combined with a common traceability concept, supports prototype functionality under the reported test conditions, not immediate construction-site deployment. Full 3D visual synchronization, BIM/GIS asset mapping, and digital-twin platform interfacing were not implemented and remain future development tasks.