The Study of Molecularly Imprinted Polymer-Based Sensor for Sensitive Detection of Glyphosate Pesticide
6
item.page.dc.date.issued
2025-01-01
item.page.dc.type
item.page.dc.identifier.issn
21568065
item.page.dc.identifier.eissn
21568073
item.page.dc.identifier.doi
item.page.dc.identifier.scopus
2-s2.0-105041273397
item.page.oaire.citation.title
Proceedings of the International Conference on Sensing Technology Icst
item.page.dc.rights.holder
SCOPUS
item.page.dc.identifier.citation
Proceedings of the International Conference on Sensing Technology Icst (2025)
punsarn.item.page.citation
Hongoeb J., Mukhopadhyay S.C., Phopin K., Tantimongcolwat T. The Study of Molecularly Imprinted Polymer-Based Sensor for Sensitive Detection of Glyphosate Pesticide. Proceedings of the International Conference on Sensing Technology Icst (2025). doi:10.1109/ICST66402.2025.11512513 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/117353
item.page.dc.title
The Study of Molecularly Imprinted Polymer-Based Sensor for Sensitive Detection of Glyphosate Pesticide
item.page.dc.contributor.author
item.page.oairecerif.author.affiliation
item.page.dc.contributor.correspondence
item.page.dc.contributor.other
item.page.dc.description.abstract
The excessive usage and persistent environmental presence of the hazardous pesticide, glyphosate, lead to significant contamination of the food chain and various ecosystems. Studies indicated the potency of this chemical to exert several severe life-threatening complications, raising health concerns throughout the globe. Unfortunately, conventional methods often suffer from expensive instrumentations, complicated operation, and lengthy analysis time. Therefore, this study proposed a simple, user-friendly, and cost-effective molecularly imprinted polymer (MIP)-modified electrode for sensitive glyphosate detection. Preliminary studies using electrochemical impedance spectroscopy (EIS) demonstrated the possibility of this approach as a promising alternative. The developed sensor revealed a working range of 0.005 to 5 μg/mL, achieving an excellent coefficient of determination (R 2) of 0.992 when utilizing the resistance parameter at a particular frequency of 5 kHz for analysis. The calculated limit of detection (LOD) of 0.437 μg/mL was also obtained. As a result, this proposed MIP-modified sensor is able to be further developed into a robust method for glyphosate detection, ultimately facilitating regulatory enforcement and safeguarding human well-being.
