Unsupervised classification of industrial boiler operation signals using dynamic time warping self-organizing map (DTW-SOM) and long short-term memory (LSTM) framework
item.page.dc.date.issued
2026-12-01
item.page.dc.type
item.page.dc.identifier.eissn
25901230
item.page.dc.identifier.doi
item.page.dc.identifier.scopus
2-s2.0-105052677781
item.page.oaire.citation.title
Results in Engineering
item.page.oaire.citation.volume
32
item.page.dc.rights.holder
SCOPUS
item.page.dc.identifier.citation
Results in Engineering Vol.32 (2026)
punsarn.item.page.citation
Nimmanterdwong P., Chalermsinsuwan B., Piemjaiswang R., Khaisri S., Takhonram C., Chaiwat W. Unsupervised classification of industrial boiler operation signals using dynamic time warping self-organizing map (DTW-SOM) and long short-term memory (LSTM) framework. Results in Engineering Vol.32 (2026). doi:10.1016/j.rineng.2026.113276 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/119523
item.page.dc.title
Unsupervised classification of industrial boiler operation signals using dynamic time warping self-organizing map (DTW-SOM) and long short-term memory (LSTM) framework
item.page.dc.contributor.author
item.page.oairecerif.author.affiliation
item.page.dc.contributor.correspondence
item.page.dc.contributor.other
item.page.dc.description.abstract
This study presents a hybrid Dynamic Time Warping Self-Organizing Map (DTW-SOM) and Long Short-Term Memory (LSTM) framework for unsupervised discovery and real-time identification of the operating state of an industrial natural-gas boiler. Nine process variables recorded were clustered with a DTW-SOM in which prototypes are updated along the optimal warping path. Seven regimes were identified: cold idle with the gas supply closed, idle with the gas line pressurized, a low-output transition, mid-load production, hot standby, stable high-load operation, and a period of suspected gas-flow sensor failure. An LSTM classifier trained on these labels, under a partition in which windows are assigned in time order within each regime episode with purge gaps at every boundary, reached an accuracy of 0.946 ± 0.026 and a macro-F1 of 0.861 ± 0.073 with the full nine-sensor input and 0.884 ± 0.038 and 0.671 ± 0.091 with a reduced four-sensor input comprising steam temperature, steam flow, exhaust-gas oxygen and exhaust-gas temperature. Class-wise results show that the reduced set identifies every firing regime as well as the full set but cannot separate the two non-firing states, which differ only in a fuel-side measurement. The framework supports mode-aware monitoring, anomaly detection and condition assessment from a compact sensor set.
