Publication:
CD4+ T-lymphocyte enumeration with a flow-rate based method in three flow cytometers with different years in service

dc.contributor.authorKovit Pattanapanyasaten_US
dc.contributor.authorPattamawan Chimmaen_US
dc.contributor.authorPanudda Sratongnoen_US
dc.contributor.authorSurada Lerdwanaen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-07-12T02:17:18Z
dc.date.available2018-07-12T02:17:18Z
dc.date.issued2008-09-01en_US
dc.description.abstractBackground: CD4+ T-lymphocyte count remains the most important surrogate marker for management of HIV patients in resource-poor countries. The standard single-platform (SP) bead-based flow cytometric method for CD4+ testing is expensive; more affordable methods are needed. We evaluated the SP flow-rate-based calibration method for determining CD4+ counts, using three flow cytometers of varying ages. Methods: CD4+ counts from 103 HIV-1 infected Thai patients were determined using a SP flow-rate method in flow cytometers with 2, 12, and 16 years of service. Results were compared to the bead-based method. Correlation and agreement were analyzed using linear regression and Bland-Altman analysis. Results: Counts obtained from the flow-rate approach in each flow cytometer showed strong correlation with the bead-based method (R2 = 0.97, 0.97, and 0.96 for the 2-, 12-, and 16-year-old flow cytometers). The mean biases for the flow-rate approach compared with the bead-based method were +32.4 cells/μL (limit of agreement (LOA): -83.0 to +147.8 cells/μL), -28.8 cells/μL (LOA: -131.6 to +74.1 cells/μL), and -27.0 cells/μL (LOA: - 149.4 to +95.4 cells/μL). Conclusion: The flow-rate approach is reliable for determining CD4+ counts. Results do not vary by age of flow cytometer. This approach provides a cost-effective alternative for HIV patient monitoring in resource-poor settings. © 2008 Clinical Cytometry Society.en_US
dc.identifier.citationCytometry Part B - Clinical Cytometry. Vol.74, No.5 (2008), 310-318en_US
dc.identifier.doi10.1002/cyto.b.20425en_US
dc.identifier.issn15524957en_US
dc.identifier.issn15524949en_US
dc.identifier.other2-s2.0-51749110853en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/18862
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=51749110853&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectMedicineen_US
dc.titleCD4+ T-lymphocyte enumeration with a flow-rate based method in three flow cytometers with different years in serviceen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=51749110853&origin=inwarden_US

Files

Collections