Publication: Highly sensitive and selective electrochemical paper-based device using a graphite screen-printed electrode modified with molecularly imprinted polymers coated Fe<inf>3</inf>O<inf>4</inf>@Au@SiO<inf>2</inf> for serotonin determination
dc.contributor.author | Maliwan Amatatongchai | en_US |
dc.contributor.author | Jirayu Sitanurak | en_US |
dc.contributor.author | Wongduan Sroysee | en_US |
dc.contributor.author | Suriyaphon Sodanat | en_US |
dc.contributor.author | S. Chairam | en_US |
dc.contributor.author | P. Jarujamrus | en_US |
dc.contributor.author | Duangjai Nacapricha | en_US |
dc.contributor.author | Peter A. Lieberzeit | en_US |
dc.contributor.other | Ubon Rajathanee University | en_US |
dc.contributor.other | Universitat Wien | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Flow Innovation-Research for Science and Technology Laboratories (Firstlabs) | en_US |
dc.date.accessioned | 2020-01-27T07:37:16Z | |
dc.date.available | 2020-01-27T07:37:16Z | |
dc.date.issued | 2019-10-24 | en_US |
dc.description.abstract | © 2019 Elsevier B.V. Herein, we propose a highly sensitive and selective three-dimensional electrochemical paper-based analytical device (3D-ePAD) to determine serotonin (Ser). It uses a graphite-paste electrode modified with nanoparticles coated with molecularly imprinted polymer (MIP). Fe3O4@Au nanoparticles were encapsulated with silica to create novel nano-sized MIP. Morphology and structural characterization reveal that silica imprinted sites (Fe3O4@Au@SiO2) synthesized via sol-gel methods provide excellent features for Ser detection, including high porosity, and greatly improve analyte diffusion and adsorption to provide a faster response by the MIP sensor. The template molecule was effectively removed by solvent extraction to provide a greater number of specific cavities that enhance analyte capacity and sensitivity. The 3D-ePAD was fabricated by alkyl ketene dimer (AKD)-inkjet printing of a circular hydrophobic detection zone on filter paper for application of aqueous samples, coupled with screen-printed electrodes on the paper, which was folded underneath the hydrophobic zone. The sensor was constructed by drop coating of Fe3O4@Au@SiO2-MIP nanocomposites on the graphite electrode (GPE) surface. The MIP sensor (Fe3O4@Au@SiO2-MIP/GPE) was used in the detection of Ser by linear-sweep voltammetry (LSV) in 0.1 M phosphate buffer at pH 8.0. The device exhibits high sensitivity toward Ser, which we attribute to synergistic effects between catalytic properties, electrical conductivity of Fe3O4@Au@SiO2, and significantly increased numbers of imprinted sites. Ser oxidation was observed at +0.39 V. Anodic peak currents for Ser show linearity from 0.01 to 1000 μM (y = 0.0075 ± 0.0049 x + 0.4071 ± 0.0052, r2 = 0.993), with a detection limit of 0.002 μM (3S/N). The device provides good repeatability (%relative standard deviations; RSD) = 4.23%, calculated from the current responses of ten different MIP sensors). The device also exhibits high selectivity and reproducibility (%RSD = 8.35%, obtained from five calibration plots). The analytical performance of the device is suitable for the determination of Ser in pharmaceutical capsules and urine samples. | en_US |
dc.identifier.citation | Analytica Chimica Acta. Vol.1077, (2019), 255-265 | en_US |
dc.identifier.doi | 10.1016/j.aca.2019.05.047 | en_US |
dc.identifier.issn | 18734324 | en_US |
dc.identifier.issn | 00032670 | en_US |
dc.identifier.other | 2-s2.0-85066778604 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/50053 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85066778604&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Environmental Science | en_US |
dc.title | Highly sensitive and selective electrochemical paper-based device using a graphite screen-printed electrode modified with molecularly imprinted polymers coated Fe<inf>3</inf>O<inf>4</inf>@Au@SiO<inf>2</inf> for serotonin determination | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85066778604&origin=inward | en_US |