Publication:
Optimizing fractional intensity threshold for FSL-Brain Extraction Tool (BET) and comparing with freeSurfer on 3D T1W MR images

dc.contributor.authorYudthaphon Vichianinen_US
dc.contributor.authorAdisorn Kareesawen_US
dc.contributor.authorOrasa Chawalpariten_US
dc.contributor.authorMasafumi Ohkien_US
dc.contributor.otherFaculty of Medicine, Siriraj Hospital, Mahidol Universityen_US
dc.contributor.otherKyushu Universityen_US
dc.date.accessioned2019-08-23T11:46:18Z
dc.date.available2019-08-23T11:46:18Z
dc.date.issued2018-09-01en_US
dc.description.abstract© 2018 Siriraj Medical Journal. Objective: To find out the optimal Brain Extraction Tool (BET) parameter (fractional intensity threshold) for measuring the brain volume compared with the standard manual method in our institute and to compare with those of automated FreeSurfer software Methods: This retrospective study was performed in 10 healthy adult subjects with data of 3D-T1W on 3T MR machine. The manual gold standard brain volume measurements were done by two independent readers. The automated segmentations using BET with varied parameters and FreeSurfer software were also performed. Then, the two automated methods were compared with the manual tracing to make the optimal parameter by seeking for the highest intraclass correlation coefficient (ICC) using SPSS software. Results: The fractional intensity threshold for whole brain volume measurement of 0.1- 0.6 showed high ICC with the manual gold standard (ranging from 0.639 to 0.748). The best value was 0.1, showing highest ICC of 0.748 (p < 0.006) with confidence interval of 95% equal to (0.242; 0.932). There were no optimal parameters for right and left hippocampus volume measurement by BET due to very low ICC between BET and the reader (ICC ranging from 0.017 to 0.139 and from 0.012 to 0.110, for the right and left hippocampus volume, respectively). The ICC values of the automated FreeSurfer method with the manual tracing were also very low (0.063, 0.068, and 0.063 for right, left and bilateral hippocampi respectively). Conclusion: The optimal BET parameter (fractional intensity threshold) for automated brain volume measurement in our institute is 0.1 similar to the suggested value by prior study with high agreement (ICC=0.748) to the manual method.en_US
dc.identifier.citationSiriraj Medical Journal. Vol.70, No.5 (2018), 391-396en_US
dc.identifier.doi10.14456/smj.2018.62en_US
dc.identifier.issn22288082en_US
dc.identifier.other2-s2.0-85057542537en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/46380
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85057542537&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleOptimizing fractional intensity threshold for FSL-Brain Extraction Tool (BET) and comparing with freeSurfer on 3D T1W MR imagesen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85057542537&origin=inwarden_US

Files

Collections