Publication:
Correlation of the ERPF with the extraction fraction values of technetium-99m mercaptoacetyltriglycine

dc.contributor.authorChanisa Chotipanichen_US
dc.contributor.authorMarc Hickesonen_US
dc.contributor.authorJehanzeb Khanen_US
dc.contributor.authorDave Beaucheminen_US
dc.contributor.authorDouglas Canningen_US
dc.contributor.authorMartin Charronen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherUniversity of Pennsylvania, Health Systemen_US
dc.contributor.otherThe Children's Hospital of Philadelphiaen_US
dc.date.accessioned2018-08-20T07:09:43Z
dc.date.available2018-08-20T07:09:43Z
dc.date.issued2006-10-11en_US
dc.description.abstractObjective: The objective of this study was to determine if a correlation exists between the effective renal plasma flow (ERPF) and the extraction fraction (EF) using 99mTc MAG3 in children. This EF has been previously described with 99mTc DTPA. However, the renal imaging agent of choice has become 99mTc MAG3. Material and Method: The study was approved by The Children's Hospital of Philadelphia's institutional review board. Informed consent was also obtained. A retrospective study of 29 children (16 males, 13 females) of ages 1 month to 19.5 years who underwent 99mTc MAG3 renal scintigraphy from September 2001 to December 2001 was analysed. EF values were calculated with and without attenuation correction in each kidney by determining the counts in a region of interest, correcting for background and comparing the counts with the injected dose. The EF was compared to the ERPF calculated using the Schlegel's method. The correlation between the EF and the ERPF, corrected and non-corrected for soft tissue attenuation, were determined and were identified by using linear regression analysis. Results: There was significant correlation between the ERPF and the EF with (r = 0.62, p < 0.05 on the left, r = 0.51, p = 0.005 on the right) than without attenuation correction (r = 0.54, p = 0.003 on the left, r = 0.42, p = 0.022 on the right). Conclusion: These results indicate a correlation of the ERPF calculated using the Schlegel's method with EF obtained from a 99mTc MAG3 renal scintigraphy. The EF may be the good alternative parameter for calculation of renal function, potentially more practical in pediatric patient and the ERPF for 99mTc MAG3 using the established software program based on Schlegel's formula.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.89, No.9 (2006), 1479-1486en_US
dc.identifier.issn01252208en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-33749446600en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/23545
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33749446600&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleCorrelation of the ERPF with the extraction fraction values of technetium-99m mercaptoacetyltriglycineen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33749446600&origin=inwarden_US

Files

Collections