Publication:
A simple method using two-step hot embossing technique with shrinking for fabrication of cross microchannels on PMMA substrate and its application to electrophoretic separation of amino acids in functional drinks

dc.contributor.authorNatta Wiriyakunen_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.authorRattikan Chantiwasen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-12-11T02:05:49Z
dc.date.accessioned2019-03-14T08:03:31Z
dc.date.available2018-12-11T02:05:49Z
dc.date.available2019-03-14T08:03:31Z
dc.date.issued2016-12-01en_US
dc.description.abstract© 2016 Elsevier B.V. This work presents a simple hot embossing method with a shrinking procedure to produce cross-shape microchannels on poly(methyl methacrylate) (PMMA) substrate for the fabrication of an electrophoresis chip. The proposed method employed a simple two-step hot embossing technique, carried out consecutively on the same piece of substrate to make the crossing channels. Studies of embossing conditions, i.e. temperature, pressure and time, were carried out to investigate their effects on the dimension of the microchannels. Applying a simple shrinking procedure reduced the size of the channels from 700±20 µm wide×150±5 µm deep to 250±10 µm wide×30±2 µm deep, i.e. 80% and 64% reduction in the depth and width, respectively. Thermal fusion was employed to bond the PMMA substrate with a PMMA cover plate to produce the microfluidic device. Replication of microchip was achieved by precise control of conditions in the fabrication process (pressure, temperature and time), resulting in lower than 7% RSD of channel dimension, width and depth (n =10 devices). The method was simple and robust without the use of expensive equipment to construct the microstructure on a thermoplastic substrate. The PMMA microchip was used for demonstration of amine functionalization on the PMMA surface, measurement of electroosmotic flow and for electrophoretic separation of amino acids in functional drink samples. The precision of migration time and peak area of the amino acids, Lys, Ile and Phe at 125 μM to 500 μM, were in the range 3.2–4.2% RSD (n=9 devices) and 4.5–5.3% RSD (n=9 devices), respectively.en_US
dc.identifier.citationTalanta. Vol.161, (2016), 574-582en_US
dc.identifier.doi10.1016/j.talanta.2016.09.001en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-84986607600en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/42470
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84986607600&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.titleA simple method using two-step hot embossing technique with shrinking for fabrication of cross microchannels on PMMA substrate and its application to electrophoretic separation of amino acids in functional drinksen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84986607600&origin=inwarden_US

Files

Collections