Publication:
A comparison of techniques for assessment of coronal dye leakage

dc.contributor.authorSuwit Wimonchiten_US
dc.contributor.authorSiriporn Timpawaten_US
dc.contributor.authorNoppakun Vongsavanen_US
dc.contributor.otherKhon Kaen Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-07-24T02:59:33Z
dc.date.available2018-07-24T02:59:33Z
dc.date.issued2002-01-01en_US
dc.description.abstractThis study was designed to compare different techniques for coronal dye leakage testing. One hundred and fifty extracted human anterior teeth were fully instrumented and randomly divided into two experimental groups of 60 teeth each, plus two groups of 15 teeth each for positive and negative controls. One group was rinsed with 5.25% NaOCl (smear layer intact), whereas the other group was flushed with 17% EDTA and 5.25% NaOCl (smear layer removed). Roots were obturated with guttapercha using lateral condensation and AH Plus as root canal sealer. Each experimental group was divided into three subgroups of 20 teeth each for three methods of testing coronal dye leakage: passive dye penetration, penetration with vacuum applied, and fluid filtration methods. The teeth were left in 100% humidity at 37°C for 5 days before being immersed in Indian ink for 2 days and cleared. The linear extent of dye penetration was measured. Mean depth of leakage for the groups with the smear layer intact was 2.5 ± 1.0 mm for passive dye penetration, 6.7 ± 2.8 mm for vacuum dye penetration, and 3.0 ± 1.1mmfor fluid filtration dye penetration. In the group in which the smear layer was removed, the mean depths of leakage were: 3.2 ± 2.1 mm for passive dye penetration, 5.8 ± 2.8 mm for vacuum dye penetration, and 3.4 ± 2.1 mm for fluid filtration. The vacuum method resulted in significantly (p < 0.05) more dye penetration than fluid filtration and passive dye penetration. The presence or absence of smear layer had no statistically significant effect (p > 0.05) on any of the leakage testing techniques. Copyright © 2002 by The American Association of Endodontists.en_US
dc.identifier.citationJournal of Endodontics. Vol.28, No.1 (2002), 1-4en_US
dc.identifier.doi10.1097/00004770-200201000-00001en_US
dc.identifier.issn00992399en_US
dc.identifier.other2-s2.0-0036363925en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/20154
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0036363925&origin=inwarden_US
dc.subjectDentistryen_US
dc.titleA comparison of techniques for assessment of coronal dye leakageen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0036363925&origin=inwarden_US

Files

Collections