Publication: AAO-CNTs electrode on microfluidic flow injection system for rapid iodide sensing
dc.contributor.author | Ditsayut Phokharatkul | en_US |
dc.contributor.author | Chanpen Karuwan | en_US |
dc.contributor.author | Tanom Lomas | en_US |
dc.contributor.author | Duangjai Nacapricha | en_US |
dc.contributor.author | Anurat Wisitsoraat | en_US |
dc.contributor.author | Adisorn Tuantranont | en_US |
dc.contributor.other | Thailand National Electronics and Computer Technology Center | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Faculty of Pharmacy | en_US |
dc.date.accessioned | 2018-05-03T08:07:23Z | |
dc.date.available | 2018-05-03T08:07:23Z | |
dc.date.issued | 2011-06-15 | en_US |
dc.description.abstract | In this work, carbon nanotubes (CNTs) nanoarrays in anodized aluminum oxide (AAO-CNTs) nanopore is integrated on a microfluidic flow injection system for in-channel electrochemical detection of iodide. The device was fabricated from PDMS (polydimethylsiloxane) microchannel bonded on glass substrates that contains three-electrode electrochemical system, including AAO-CNTs as a working electrode, silver as a reference electrode and platinum as an auxiliary electrode. Aluminum, stainless steel catalyst, silve r and platinum layers were sputtered on the glass substrate through shadow masks. Aluminum layer was then anodized by two-step anodization process to form nanopore template. CNTs were then grown in AAO template by thermal chemical vapor deposition. The amperometric detection of iodide was performed in 500-μm-wide and 100-μm-deep microchannels on the microfluidic chip. The influences of flow rate, injection volume and detection potential on the current response were optimized. From experimental results, AAO-CNTs electrode on chip offers higher sensitivity and wider dynamic range than CNTs electrode with no AAO template. © 2011 Elsevier B.V. All rights reserved. | en_US |
dc.identifier.citation | Talanta. Vol.84, No.5 (2011), 1390-1395 | en_US |
dc.identifier.doi | 10.1016/j.talanta.2011.03.071 | en_US |
dc.identifier.issn | 00399140 | en_US |
dc.identifier.other | 2-s2.0-79958133658 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/11712 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79958133658&origin=inward | en_US |
dc.subject | Chemistry | en_US |
dc.title | AAO-CNTs electrode on microfluidic flow injection system for rapid iodide sensing | en_US |
dc.type | Conference Paper | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79958133658&origin=inward | en_US |