Publication:
Efficiency of the glutaraldehyde test strip for monitoring the concentration of glutaraldehyde in reused solutions for disinfecting endoscopes

dc.contributor.authorAnuwat Keerasuntonpongen_US
dc.contributor.authorAngkana Chaipraserten_US
dc.contributor.authorPratya Sitaposaen_US
dc.contributor.authorVisanu Thamlikitkulen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-07-24T03:03:55Z
dc.date.available2018-07-24T03:03:55Z
dc.date.issued2002-11-01en_US
dc.description.abstractBackground: Glutaraldehyde has been widely used for low-temperature disinfection of endoscopes. The current practice at Siriraj Hospital is to change the glutaraldehyde solution every 21 days or when the solution appears turbid. The disadvantages of this practice include inadequate disinfection of endoscopes if the concentration of glutaraldehyde in a reused solution is insufficient or wasted if the discarded solution is still active. Objective: To determine the efficiency of a glutaraldehyde test strip (GTS) in monitoring the amount of glutaraldehyde in a reused solution for disinfecting endoscopes. Method: Reused glutaraldehyde solutions for disinfecting bronchoscopes, gastroscopes and colonoscopes were tested for the concentration of glutaraldehyde with a GTS thrice weekly for the first week and then every working day up to 56 days. If the GTS indicated a concentration of glutaraldehyde ≥ 1.8 per cent after 21 days, 5 ml of the solution was taken to the laboratory to determine its mycobactericidal activity. Results: All samples of the reused glutaraldehyde solution up to 56 days with a concentration of ≥ 1.8 per cent glutaraldehyde on GTS from testings showed mycobactericidal activity. If the glutaraldehyde solution was reused for up to 28, 42 or 56 days, it could save 9,603; 22,813 and 29,415 baht per year respectively for the gastroscopy and colonoscopy units. The corresponding figures were -949; 2,726 and 4,564 baht per year for the bronchoscopy unit. It is estimated that up to 400,000 baht per year could be saved by adopting the strategy of GTS monitoring in all endoscopy units at Siriraj Hospital. Conclusion: The current strategy of discarding reused glutaraldehyde solution in the gastroscopy, colonoscopy and bronchoscopy units at Siriraj Hospital may be inappropriate since the reused solution is still mycobactericidal for up to 56 days.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.85, No.11 (2002), 1164-1168en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-0036881372en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/20306
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0036881372&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleEfficiency of the glutaraldehyde test strip for monitoring the concentration of glutaraldehyde in reused solutions for disinfecting endoscopesen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0036881372&origin=inwarden_US

Files

Collections