Publication:
Design of hip simulation machine for hip labrum testing

dc.contributor.authorChanatkarn Angsutanasombaten_US
dc.contributor.authorPanya Aroonjaratthamen_US
dc.contributor.authorNadhaporn Saengpetchen_US
dc.contributor.authorPornsak Nirunsuken_US
dc.contributor.authorKitti Aroonjaratthamen_US
dc.contributor.authorChompunut Somtuaen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherBurapha Universityen_US
dc.date.accessioned2019-08-23T11:07:56Z
dc.date.available2019-08-23T11:07:56Z
dc.date.issued2018-03-30en_US
dc.description.abstract© 2018, Chulalongkorn University. All rights reserved. The acetabular labrum is the connective tissue between femoral head and hip joint that acts like a shock absorber. Labral injury could happen after hip dislocation or internal derangement such as femeroacetabular impingement (FAI) syndrome. The surgeon usually attempts to repair or reconstruct the torn labrum to obtain the native hip biomechanical loading. There has been no scientific evidence study for the different surgical techniques. Hip simulation machine was made to let a femur move in six conditions including flexion, extension, abduction, adduction, internal rotation and external rotation. The hip was compressed with a force of half of the body weight (350 N). The purpose of this study was to study pressurization in three labral conditions including intact labrum, labral repair and labral reconstruction. The machine was designed and simulated by SolidWorks software. A device’s controller had two mode including a manual mode to set zero before an operation and automation mode to move in six conditions and compressed with a force of body weight. After the construction, the machine was tasted by using counterfeit pelvis and femur. The device was reformed before a real taste. Dissected cadaveric pelvises were used and measured pressure through the film piezoresistive load sensors. The testing result was helped the surgeon to make a decision in surgery process.en_US
dc.identifier.citationEngineering Journal. Vol.22, No.2 (2018), 117-130en_US
dc.identifier.doi10.4186/ej.2018.22.2.117en_US
dc.identifier.issn01258281en_US
dc.identifier.other2-s2.0-85049181297en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/45815
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85049181297&origin=inwarden_US
dc.subjectEngineeringen_US
dc.titleDesign of hip simulation machine for hip labrum testingen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85049181297&origin=inwarden_US

Files

Collections