Publication:
Percutaneous Balloon Pulmonary Valvuloplasty in Children : Experience at Siriraj Hospital

dc.contributor.authorDuangmanee Laohaprasitipornen_US
dc.contributor.authorApichart Nanaen_US
dc.contributor.authorJarupim Soongsawangen_US
dc.contributor.authorCharuwan Kangkagateen_US
dc.contributor.authorKanchana Wansaniten_US
dc.contributor.authorTiranach Kovitcharoentrakulen_US
dc.contributor.authorBurin Kaosaarden_US
dc.contributor.authorSukanya Pooranawatanakulen_US
dc.contributor.authorSiriluck Suriyabantheongen_US
dc.contributor.otherDivision of Cardiologyen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-07-04T07:48:44Z
dc.date.available2018-07-04T07:48:44Z
dc.date.issued1997-09-01en_US
dc.description.abstractTwenty-seven children with pulmonary valvar stenosis with pressure gradient (PG) ≥ 40 mmHg underwent percutaneous balloon pulmonary valvuloplasty (PBPV) at Siriraj Hospital between February 1993 and August 1996. There were 13 males and 14 females, with an age range from 2 months to 14 years, and body weight from 4.7 to 42.1 kg. The majority (92.6%) were asymptomatic. Before the PBPV, the pulmonary valve annulus (PVA) measured by echocardiography was significantly greater than that measured by cardiac catheterization (15.2 ±3.7 vs 14.5 ± 3.9 mm, P = 0.006). However, there was linear association (r = 0.972) between the two methods. The PG obtained by the two methods showed no significant difference (90.8 ± 35.3 by echocardiography vs 97.3 ± 47.2 mmHg by catheterization, P = 0.266). Immediately after PBPV, the right ventricular systolic pressure (113.7 ± 41.1 pre vs 62.3 ± 28.1 mmHg post) and the PG 103.4 ± 43.4 pre vs 49.0 ± 31.1 mmHg post) were significantly reduced (p ≤ 0.0005). At 6-mo follow-up echocardiography, the PG was 28.6 ± 17.6 mmHg and was significantly reduced (P = 0.0005). The PVA significantly increased at the 12 mo follow-up (15.2 ± 3.6 pre vs 17.6 ± 3.8 mm post, P = 0.001). Only minor complications were reported in the present study; bleeding (3.7%), transient bradycardia (7.4%) and pulmonary regurgitation not more than moderate severity (79%). The immediate and intermediate results of PBPV are excellent with a success rate of 85 per cent.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.80, No.9 (1997), 580-585en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-0031218665en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/18097
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0031218665&origin=inwarden_US
dc.subjectMedicineen_US
dc.titlePercutaneous Balloon Pulmonary Valvuloplasty in Children : Experience at Siriraj Hospitalen_US
dc.typeArticleen_US