Publication:
Utility of adding SPECT/CT imaging to post-therapeutic radioiodine whole-body scan in patients with differentiated thyroid cancer

dc.contributor.authorJiraporn Sriprapapornen_US
dc.contributor.authorChakmeedaj Sethanandhaen_US
dc.contributor.authorTawee Yingsa-Ngaen_US
dc.contributor.authorChulaluk Komoltrien_US
dc.contributor.authorThonnapong Thongpraparnen_US
dc.contributor.authorChompunoot Harnnanthawiwaten_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-11-23T10:53:10Z
dc.date.available2018-11-23T10:53:10Z
dc.date.issued2015-01-01en_US
dc.description.abstract© 2015, Medical Association of Thailand. All rights reserved. Objective: To determine the usefulness of adding single-photon emission computed tomography/computed tomography (SPECT/CT) imaging to post-therapeutic radioiodine whole-body scan (RxWBS) in patients with differentiated thyroid cancer. Material and Method: RxWBSs and SPECT/CT images of 93 consecutive patients were reviewed retrospectively by three experienced nuclear medicine physicians without knowledge of clinical data. RxWBSs were reviewed first followed by evaluation of RxWBS plus SPECT/CT imaging. Foci of increased radioiodine uptake were identified and localization was attempted. The findings obtained from RxWBS were compared with WBS plus SPECT/CT imaging to determine impact on lesion characterization, TNM staging, and management plan. Results: Two hundred seventy seven lesions were identified by RxWBS alone. RxWBS plus SPECT/CT imaging detected eight additional pathologic lesions (4 in bones, two in neck, and one in lung and thyroid bed). RxWBS plus SPECT/CT studies reclassified 85 of 277 lesions (30.7%) detected by RxWBS. Most change occurred in neck region (57 lesions) followed by chest region (16 lesions). For impact on TNM staging, RxWBS plus SPECT/CT studies changed N stage of 21 patients (22.6%) and reclassified M stage of 10 patients (10.8%). These resulted in change of TNM stage group of 14 patients (15.1%) and changed management plan of 19 patients (20.4%). Conclusion: The addition of SPECT/CT imaging to RxWBS in patients with differentiated thyroid cancer improved disease localization and lesion characterization leading to more accurate N and M staging, which was mainly downstaged. SPECT/CT also had impact on plan of management in about one fifth of the patients. However, caution should be taken when interpreting lesion in lower chest and upper abdomen because misregistration of SPECT and CT images.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.98, No.6 (2015), 596-605en_US
dc.identifier.issn01252208en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-84933514554en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/36577
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84933514554&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleUtility of adding SPECT/CT imaging to post-therapeutic radioiodine whole-body scan in patients with differentiated thyroid canceren_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84933514554&origin=inwarden_US

Files