Publication: The efficacy of the WhisperFlow CPAP system versus high flow nasal cannula in patients at risk for postextubation failure: A Randomized controlled trial
dc.contributor.author | Pongdhep Theerawit | en_US |
dc.contributor.author | Nattawat Natpobsuk | en_US |
dc.contributor.author | Tananchai Petnak | en_US |
dc.contributor.author | Yuda Sutherasan | en_US |
dc.contributor.other | Faculty of Medicine Ramathibodi Hospital, Mahidol University | en_US |
dc.contributor.other | Maharaj Nakhon Ratchasima Hospital | en_US |
dc.date.accessioned | 2022-08-04T09:23:43Z | |
dc.date.available | 2022-08-04T09:23:43Z | |
dc.date.issued | 2021-06-01 | en_US |
dc.description.abstract | Purpose: Compare the efficacy(reintubation rate) between a high-flow nasal cannula(HFNC) and the WhisperFlow CPAP system in patients at risk for postextubation failure. Material and methods: RCT was conducted in patients who had at least one high-risk criterion for postextubation failure. All patients were randomly assigned to CPAP or HFNC for 48 h. Results: Of 140 patients, sixty-nine were assigned to the CPAP group and 71 to the HFNC group. The reintubation rate was similar between the HFNC and WhisperFlowCPAP [5 cases(7.0%) vs. 6 cases(8.7%); P = 0.76]. The postextubation respiratory failure rate was not significantly different between the HFNC and WhisperFlow CPAP groups [10 cases(14.1%)vs.7cases(10.1%); P = 0.48]. The respiratory rate was lower in the HFNC than CPAP group(P = 0.04). The pain rating scale score was lower in the HFNC group than in the WhisperFlow CPAP group at 24 h (2.8 ± 2.0 vs. 3.7 ± 1.9, P = 0.02) and 48 h (2.8 ± 1.8 vs. 3.8 ± 1.9, P = 0.002). Conclusions: We are unable to demonstrate a reduction in postextubation respiratory failure in at risk patients with the use of HFNC compared with the WhisperFlow CPAP system probably because small sample size, but HFNC was better tolerated. | en_US |
dc.identifier.citation | Journal of Critical Care. Vol.63, (2021), 117-123 | en_US |
dc.identifier.doi | 10.1016/j.jcrc.2020.09.031 | en_US |
dc.identifier.issn | 15578615 | en_US |
dc.identifier.issn | 08839441 | en_US |
dc.identifier.other | 2-s2.0-85092172239 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/78194 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85092172239&origin=inward | en_US |
dc.subject | Medicine | en_US |
dc.title | The efficacy of the WhisperFlow CPAP system versus high flow nasal cannula in patients at risk for postextubation failure: A Randomized controlled trial | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85092172239&origin=inward | en_US |