Publication:
Determination of irinotecan, SN-38 and SN-38 glucuronide using HPLC/MS/MS: Application in a clinical pharmacokinetic and personalized medicine in colorectal cancer patients

dc.contributor.authorChalirmporn Atasilpen_US
dc.contributor.authorPichai Chansriwongen_US
dc.contributor.authorEkapob Sirachainanen_US
dc.contributor.authorThanyanan Reungwetwattanaen_US
dc.contributor.authorApichaya Puangpetchen_US
dc.contributor.authorSantirhat Prommasen_US
dc.contributor.authorSuwannee Sirilerttrakulen_US
dc.contributor.authorBudsaba Rerkarmnuaychokeen_US
dc.contributor.authorSansanee Wongwaisayawanen_US
dc.contributor.authorChonlaphat Sukasemen_US
dc.contributor.otherFaculty of Medicine, Ramathibodi Hospital, Mahidol Universityen_US
dc.date.accessioned2019-08-23T10:39:30Z
dc.date.available2019-08-23T10:39:30Z
dc.date.issued2018-01-01en_US
dc.description.abstract© 2017 Wiley Periodicals, Inc. Background: Irinotecan (CPT-11) is chemotherapy used mainly in the metastatic colorectal cancer. The purpose of this study was to develop and validate the LC-MS/MS for the simultaneous determination of CPT-11, SN-38, and SN-38G. Methods: A 100 μL of plasma was prepared after protein precipitation and analyzed on a C18 column using 0.1% acetic acid in water and 0.1% acetic acid in acetonitrile as mobile phases. The mass spectrometer worked with multiple reaction monitoring (MRM) in positive scan mode. The standard curves were linear on a concentration range of 5-10 000 ng/mL for CPT-11, 5-1000 ng/mL for SN-38, and 8-1000 ng/mL for SN-38G. Results: In this assay, the intra and interday precision consisted of ≤9.11% and ≤11.29% for CPT-11, ≤8.70% and 8.31% for SN-38, and ≤9.90 and 9.64% for SN-38G. Conclusion: This method was successfully used to quantify CPT-11, SN-38, and SN-38G and applied to a pharmacokinetic study.en_US
dc.identifier.citationJournal of Clinical Laboratory Analysis. Vol.32, No.1 (2018)en_US
dc.identifier.doi10.1002/jcla.22217en_US
dc.identifier.issn10982825en_US
dc.identifier.issn08878013en_US
dc.identifier.other2-s2.0-85017550574en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/45295
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85017550574&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectHealth Professionsen_US
dc.subjectMedicineen_US
dc.titleDetermination of irinotecan, SN-38 and SN-38 glucuronide using HPLC/MS/MS: Application in a clinical pharmacokinetic and personalized medicine in colorectal cancer patientsen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85017550574&origin=inwarden_US

Files

Collections