Publication:
Assessment of the reliability of automatic cephalometric analysis software

dc.contributor.authorNiwat Anuwongnukrohen_US
dc.contributor.authorSurachai Dechkunakornen_US
dc.contributor.authorSuchaya Damrongsrien_US
dc.contributor.authorChayawat Nilwaraten_US
dc.contributor.authorNatthasit Pudpongen_US
dc.contributor.authorWatcharapon Radomsutthisarnen_US
dc.contributor.authorSilinda Kangernen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2019-08-23T10:58:35Z
dc.date.available2019-08-23T10:58:35Z
dc.date.issued2018-01-01en_US
dc.description.abstract© 2018 Int. J. Mech. Eng. Rob. Res. The aim of this study was to evaluate and compare the reliability of a fully automatic cephalometric analysis software with manual cephalometric tracing. The lateral cephalograms of 108 orthodontic patients were selected. Eight linear (Pg-NB, Co-A, Co-Gn, U1-NA, L1-NB, Lower lip to E-plane, S-Go, and N-Me) and 9 angular (NS-Ba, SNA, SNB, NS-MP, FH-FO, U1-NA, L1-NB, L1-MP, and U1-L1) measurements were used in this study. The cephalometric analyses were performed by both manual method and automatic software. The differences between two methods were compared by paired t-test with p < 0.05. Analysis of interexaminer calibration of the measurement revealed a high reliability. The result showed that there were statistically significant differences (p < 0.05) in 13/17 parameters between the two methods, which consisted of 6 linear parameters (Pg-NB, Co-A, Co-Gn, U1-NA, L1-NB, and Lower lip to E-plane) and 7 angular parameters (SNA, NS-MP, FH-FO, U1-NA, L1-NB, L1-MP, and U1-L1). Only 4 parameters (NS-Ba, SNB, S-Go, and N-Me) did not show any significant differences. It is summarized that 76.47% (13/17 parameters) of cephalometric measurements performed automatically by the dental imaging software showed statistically significant differences when compared with the manual method. The automatic software could not reliably locate all cephalometric landmarks. Hence, the clinicians should not rely on the fully automatic analysis mode since the algorithm of the software still needs improvement for the higher accuracy in locating the cephalometric landmarks. Thus, to obtain accurate results, manual adjustments to the automatically located cephalometric landmarks are recommended.en_US
dc.identifier.citationInternational Journal of Mechanical Engineering and Robotics Research. Vol.7, No.1 (2018), 61-65en_US
dc.identifier.doi10.18178/ijmerr.7.1.61-65en_US
dc.identifier.issn22780149en_US
dc.identifier.other2-s2.0-85040337616en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/45670
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85040337616&origin=inwarden_US
dc.subjectComputer Scienceen_US
dc.subjectEngineeringen_US
dc.titleAssessment of the reliability of automatic cephalometric analysis softwareen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85040337616&origin=inwarden_US

Files