Publication:
Design, development and evaluation of an automatic fruit-juice pasteurization system using microwave – ultrasonic waves

dc.contributor.authorBahram Hosseinzadeh Samanien_US
dc.contributor.authorMohammad Hadi Khoshtaghazaen_US
dc.contributor.authorSaeid Minaeien_US
dc.contributor.authorHemad Zareifouroshen_US
dc.contributor.authorMohammad Naghi Eshtiaghien_US
dc.contributor.authorSajad Rostamien_US
dc.contributor.otherTarbiat Modares Universityen_US
dc.contributor.otherShahrekord Universityen_US
dc.contributor.otherThe University of Guilanen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-12-11T02:03:22Z
dc.date.accessioned2019-03-14T08:02:37Z
dc.date.available2018-12-11T02:03:22Z
dc.date.available2019-03-14T08:02:37Z
dc.date.issued2016-01-01en_US
dc.description.abstract© 2015, Association of Food Scientists & Technologists (India). Conventional pasteurization treatments often lead to substantial decrease in fruits juice quality. Due to these issues, the objective of this research was to compare the combined effect of a novel thermal (microwave) and non-thermal (ultrasonic) treatments with conventional thermal pasteurization on some qualitative characteristics of sour cherry juice (vitamins, phenolics, anthocyanins, etc.). For this purpose, an automatic control system comprising of ultrasonic generator, ultrasonic transducer, horn, pump, circulator, microwave oven, container, pipe interface, temperature sensor, float, data acquisition card, microwave power control circuit, and reactor was designed and developed. Moreover, in order to optimize the effect of ultrasonic waves on the existing micro-organisms in the sour cherry juice, some preliminary experiments were carried out to optimize the ultrasonic probe and reactor design. The results of evaluations showed that using the combined automatic system, the qualitative properties of sour cherry (vitamin C content 14 %, total phenolics content 1 %, total anthocyanins content 6 %) can be better maintained compared with the conventional thermal method. Based on the results obtained in this study, the following processing conditions: microwave power of 541.7 W, temperature of 41 °C, ultrasonic power of 799.57 W and ultrasonic exposure time of 6 min were recommended for optimum processing of sour cherry juice.en_US
dc.identifier.citationJournal of Food Science and Technology. Vol.53, No.1 (2016), 88-103en_US
dc.identifier.doi10.1007/s13197-015-2026-6en_US
dc.identifier.issn09758402en_US
dc.identifier.issn00221155en_US
dc.identifier.other2-s2.0-84954364234en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/41647
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84954364234&origin=inwarden_US
dc.subjectAgricultural and Biological Sciencesen_US
dc.titleDesign, development and evaluation of an automatic fruit-juice pasteurization system using microwave – ultrasonic wavesen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84954364234&origin=inwarden_US

Files

Collections