Publication:
Comparison of white spot syndrome virus PCR-detection methods that use electrophoresis or antibody-mediated lateral flow chromatographic strips to visualize PCR amplicons

dc.contributor.authorJiraporn Srisalaen_US
dc.contributor.authorPhilip Taconen_US
dc.contributor.authorTimothy W. Flegelen_US
dc.contributor.authorKallaya Sritunyalucksanaen_US
dc.contributor.otherThailand National Center for Genetic Engineering and Biotechnologyen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-07-12T02:28:43Z
dc.date.available2018-07-12T02:28:43Z
dc.date.issued2008-11-01en_US
dc.description.abstractWhite spot syndrome virus (WSSV) PCR-detection methods that used electrophoresis or lateral flow chromatographic strips (LFCS) were to compare and visualize PCR amplicons. Real-time PCR was used to prepare a stock template solution containing 2.85 × 106copies WSSV/μl from WSSV-infected shrimp. Serial stock dilutions were used as templates for PCR amplification of a WSSV-specific DNA fragment that was detected either in ethidium bromide stained agarose electrophoresis gels or on a chromatographic strip where it interacted with antibody to markers labeled on hybridization complex. PCR amplification employed both 1-step PCR and semi-nested PCR methods. By using 1-step PCR, the LFCS method (100 copies) gave 10 times higher sensitivity than gel electrophoresis (103copies). A combination of a semi-nested PCR with LFCS gave a comparable sensitivity to those with commercial kits for nested PCR (20 copies). In addition, LFCS confirmed amplicon identity, avoided handling of carcinogenic ethidium bromide and could be completed in approximately 20-30 min post-PCR compared with 1 h for gel electrophoresis. The costs for the two methods were comparable. In conclusion, semi-nested PCR followed by LFCS is a safe and rapid alternative method for detection of WSSV that provides sensitivity similar to that obtained by standard nested PCR methods. © 2008 Elsevier B.V. All rights reserved.en_US
dc.identifier.citationJournal of Virological Methods. Vol.153, No.2 (2008), 129-133en_US
dc.identifier.doi10.1016/j.jviromet.2008.07.027en_US
dc.identifier.issn01660934en_US
dc.identifier.other2-s2.0-53249107533en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/19277
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=53249107533&origin=inwarden_US
dc.subjectImmunology and Microbiologyen_US
dc.titleComparison of white spot syndrome virus PCR-detection methods that use electrophoresis or antibody-mediated lateral flow chromatographic strips to visualize PCR ampliconsen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=53249107533&origin=inwarden_US

Files

Collections