Publication: Performance of packed bed column using Chara aculeolata biomass for removal of Pb and Cd ions from wastewater
dc.contributor.author | Najjapak Sooksawat | en_US |
dc.contributor.author | Metha Meetam | en_US |
dc.contributor.author | Maleeya Kruatrachue | en_US |
dc.contributor.author | Prayad Pokethitiyook | en_US |
dc.contributor.author | Duangrat Inthorn | en_US |
dc.contributor.other | Rajamangala University of Technology Tawan-ok | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | South Carolina Commission on Higher Education | en_US |
dc.date.accessioned | 2018-12-21T07:45:55Z | |
dc.date.accessioned | 2019-03-14T08:03:43Z | |
dc.date.available | 2018-12-21T07:45:55Z | |
dc.date.available | 2019-03-14T08:03:43Z | |
dc.date.issued | 2017-05-12 | en_US |
dc.description.abstract | © 2017 Taylor & Francis Group, LLC. Biosorption of Pb and Cd from aqueous solution by biomass of Chara aculeolata was studied in a continuous packed bed column. C. aculeolata in the fixed bed column is capable of decreasing Pb and Cd concentrations from 10 mg/L to a value below the detection limit of 0.02 mg/L. Selective uptake of Pb and Cd in a binary solution resulted in Pb having much higher relative affinity than Cd. The experiments were conducted to study the effects of column design parameters, bed depth, and flow rate on the metal biosorption. Pb uptake capacity of C. aculeolata increased with increased bed depth and decreased flow rate, while Cd uptake capacity increased with increased bed depth but remained constant at any flow rate. The Thomas model was found in a suitable fitness with the experiment data for Pb and Cd (R2> 0.90). The efficiency of biosorbent regeneration achieved by 0.1 M HCl was very high, that was, 98% for Pb and 100% for Cd in the third reused cycle. It can be concluded that C. aculeolata is a good biosorbent for treating wastewater having low concentrations of Pb and Cd contamination. | en_US |
dc.identifier.citation | Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering. Vol.52, No.6 (2017), 539-546 | en_US |
dc.identifier.doi | 10.1080/10934529.2017.1282774 | en_US |
dc.identifier.issn | 15324117 | en_US |
dc.identifier.issn | 10934529 | en_US |
dc.identifier.other | 2-s2.0-85013356893 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/42691 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85013356893&origin=inward | en_US |
dc.subject | Environmental Science | en_US |
dc.title | Performance of packed bed column using Chara aculeolata biomass for removal of Pb and Cd ions from wastewater | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85013356893&origin=inward | en_US |