Publication:
Simple sequential injection analysis system for rapid determination of microalbuminuria

dc.contributor.authorWanida Laiwattanapaisalen_US
dc.contributor.authorUsakorn Kunanuvaten_US
dc.contributor.authorWichabhorn Intharachutien_US
dc.contributor.authorChakorn Chinvongamornen_US
dc.contributor.authorSupot Hannongbuaen_US
dc.contributor.authorOrawon Chailapakulen_US
dc.contributor.otherChulalongkorn Universityen_US
dc.contributor.otherRajamangala University of Technology Thanyaburi (RMUTT)en_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-09-13T06:30:23Z
dc.date.available2018-09-13T06:30:23Z
dc.date.issued2009-09-15en_US
dc.description.abstractA simple, specific and sensitive sequential injection analysis (SIA) system based on non-immunoassay fluorescent detection has been developed for the determination of urinary albumin. The specific binding of the dye Albumin Blue 580 (AB 580) to albumin in urine generated high emission fluorescent signals. The excitation and emission wavelengths were set at 590 and 610 nm, respectively. The analytical range was obtained from 1 to 100 mg L-1, with a detection limit of 0.3 mg L-1(S/N = 3). The SIA system gave high precision with relative standard deviations (R.S.D.s) of 0.9% and 1.4% when evaluated with 15 and 100 mg L-1albumin (n = 15), respectively. The method exhibited good reproducibility, as assessed by performing four analytical curves on different days, and intra-run CVs (2.3-3.3%) and inter-run CVs (3.8%) were obtained. Rapid operation was achieved with a sample throughput of 37 h-1. This method was successfully applied to the determination of urinary albumin, and the method was highly correlated with the immunoturbidimetric method (r2= 0.965; n = 72). © 2009 Elsevier B.V. All rights reserved.en_US
dc.identifier.citationTalanta. Vol.79, No.4 (2009), 1104-1110en_US
dc.identifier.doi10.1016/j.talanta.2009.02.020en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-67650119673en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/27398
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=67650119673&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleSimple sequential injection analysis system for rapid determination of microalbuminuriaen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=67650119673&origin=inwarden_US