Publication:
How to close a colpotomy? Barbed suture and conventional suture eVects on soft tissue: An ex vivo pilot study

dc.contributor.authorChenchit Chayachindaen_US
dc.contributor.authorAndreas Hackethalen_US
dc.contributor.authorHans Rudolf Tinnebergen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherJustus Liebig University Giessenen_US
dc.date.accessioned2018-06-11T05:10:06Z
dc.date.available2018-06-11T05:10:06Z
dc.date.issued2012-06-01en_US
dc.description.abstractObjective To evaluate the eVects of diVerent suture materials and techniques on soft tissue in relation to deWned tensions and time points. Materials and methods Two bovine intestine samples, 4 £ 4 cm size and 3 mm thickness, were adapted with interrupted and continuous techniques using three types of suture materials: Vicryl (polyglactin 910), PDS II (polydi-oxanone), and V-Loc 180 (knotless, barbed polyglyconate). Four stitches or loops 9 mm apart with three knots, and 10 mm end length were performed by one gynecologist. Forces were applied from 6 newtons (N) to 14 N continuously. Outcome measures included breakage of tissue, tearing of thread, and shortening of the end length of thread. They were evaluated immediately and then at Wrst, third, and Wfth minute. Results Tissue breakage using No. 3/0 suture materials appears in the applied force from 10 N. polydioxanone causes more tissue tearing than polyglactin 910. The least to withstand tension is knotless polyglyconate. Interrupted stitches hold the sutured sites better than continuous stitches in all groups of threads. Shortening of the knotless polyglyconate end length by half took place with 6 N force. Conclusion Simulating reparation of colpotomy, the ex vivo study supports that polyglactin 910 appears better in holding soft tissue than polydioxanone and knotless poly-glyconate. © 2012 Springer-Verlag.en_US
dc.identifier.citationArchives of Gynecology and Obstetrics. Vol.285, No.6 (2012), 1633-1636en_US
dc.identifier.doi10.1007/s00404-012-2214-9en_US
dc.identifier.issn14320711en_US
dc.identifier.issn09320067en_US
dc.identifier.other2-s2.0-84864432691en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/14779
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84864432691&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleHow to close a colpotomy? Barbed suture and conventional suture eVects on soft tissue: An ex vivo pilot studyen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84864432691&origin=inwarden_US

Files

Collections