Publication:
Determination of the centre of resistance during en masse retraction combined with corticotomy: finite element analysis

dc.contributor.authorTanes Ouejiaraphanten_US
dc.contributor.authorBancha Samruajbenjakunen_US
dc.contributor.authorEkachai Chaichanasirien_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherPrince of Songkla Universityen_US
dc.date.accessioned2019-08-23T11:01:18Z
dc.date.available2019-08-23T11:01:18Z
dc.date.issued2018-01-02en_US
dc.description.abstract© 2017 British Orthodontic Society. Objective: To determine the effect of corticotomy on the change in the centre of resistance of the six maxillary anterior teeth Materials and methods: Three-dimensional finite element models of the maxillary anterior teeth with and without corticotomy were constructed. Brackets (size 0.022 inch × 0.028 inch) were placed passively on all anterior teeth that were set at the centre of the labial surface in the mesio-distal dimension and 3 mm from the incisal edge to the bracket slot in the vertical direction. The power arm was set mesial of the canine bracket. For the model with corticotomy, the bone density was decreased from initial value at 5% to 25%. The point of force application was varied in order to locate the centre of resistance. The centre of resistance was located by measurement of the difference of the displacement between the apical and incisal edges. The position of force was varied by moving apically parallel to the occlusal plane to simulate tooth movement. Results: As the alveolar bone density decreased from initial value to 25%, the location of the centre of resistance moved apically from the bracket slot from 10.8 mm to 11.2 mm, respectively. Conclusions: The change of alveolar bone density due to corticotomy was associated with the location of the centre of resistance. The location of the centre of resistance moved apically as the alveolar bone density decreased but it was not clinically noticeable.en_US
dc.identifier.citationJournal of Orthodontics. Vol.45, No.1 (2018), 11-15en_US
dc.identifier.doi10.1080/14653125.2017.1405138en_US
dc.identifier.issn14653133en_US
dc.identifier.issn14653125en_US
dc.identifier.other2-s2.0-85034651897en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/45721
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85034651897&origin=inwarden_US
dc.subjectDentistryen_US
dc.titleDetermination of the centre of resistance during en masse retraction combined with corticotomy: finite element analysisen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85034651897&origin=inwarden_US

Files

Collections