Publication:
An automated catalytic spectrophotometric method for manganese analysis using a chip-multisyringe flow injection system (Chip-MSFIA)

dc.contributor.authorPiyawan Phansien_US
dc.contributor.authorCamelia Henríquezen_US
dc.contributor.authorEdwin Palacioen_US
dc.contributor.authorPrapin Wilairaten_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.authorVíctor Cerdàen_US
dc.contributor.otherFlow Innovation-Research for Science and Technology Laboratories (FIRST Labs.en_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherUniversitat de les Illes Balearsen_US
dc.date.accessioned2018-11-09T02:03:09Z
dc.date.available2018-11-09T02:03:09Z
dc.date.issued2014-07-21en_US
dc.description.abstractIn this work, we present an automated catalytic spectrophotometric method for determination of Mn(ii) by using a multisyringe burette coupled to a chip microfluidic-conductor (Chip-MSFIA). The reaction is based on the catalytic effect of Mn(ii) on the auto-oxidation reaction of succinimidedioxime (SIDO). Reagents and the sample were simultaneously dispensed to the chip for their complete mixing, heating, and measurement. The absorbance of the reaction product was measured at 700 nm. The product concentration could be determined by the fixed-time and the initial rate method under optimum conditions (temperature 35°C, 4.70 mmol L-1 SIDO, and 0.60 mol L -1 NaOH). Both fixed-time and initial rate methods have been developed, with the fixed-time method giving higher reproducibility and a wider working range. Therefore it was selected for Mn(ii) samples in the working range of 1-20 μg L-1 of Mn(ii). The estimated precision was 0.67% (5 μg L-1, n = 15) and the limit of detection of Mn(ii) was 0.33 μg L-1. The proposed method is highly sensitive, selective, and simple for trace Mn(ii) determination without extraction and separation steps. The system was successfully applied to water samples with an injection throughput of 22 injections h-1. © 2014 The Royal Society of Chemistry.en_US
dc.identifier.citationAnalytical Methods. Vol.6, No.14 (2014), 5088-5096en_US
dc.identifier.doi10.1039/c4ay00624ken_US
dc.identifier.issn17599679en_US
dc.identifier.issn17599660en_US
dc.identifier.other2-s2.0-84903589770en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/33562
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84903589770&origin=inwarden_US
dc.subjectChemical Engineeringen_US
dc.subjectChemistryen_US
dc.subjectEngineeringen_US
dc.titleAn automated catalytic spectrophotometric method for manganese analysis using a chip-multisyringe flow injection system (Chip-MSFIA)en_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84903589770&origin=inwarden_US

Files

Collections