Publication:
Gold-nanoparticle-based fiber optic sensor for sensing the refractive index of environmental solutions

dc.contributor.authorNongluck Houngkamhangen_US
dc.contributor.authorSittan Charoensuwanen_US
dc.contributor.authorOnanong Sonthipakdeeen_US
dc.contributor.authorKawin Nawattanapaiboonen_US
dc.contributor.authorArmote Somboonkaewen_US
dc.contributor.authorRatthasart Amariten_US
dc.contributor.otherKing Mongkut's Institute of Technology Ladkrabangen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherThailand National Electronics and Computer Technology Centeren_US
dc.date.accessioned2019-08-23T10:30:06Z
dc.date.available2019-08-23T10:30:06Z
dc.date.issued2018-08-01en_US
dc.description.abstract© 2018, Chiang Mai University. All rights reserved. Here an optical fiber modified with gold nanoparticles was successfully fabricated to sense the refractive index of a chemical solution surrounding its surface, with the potential of utilizing this sensor as a biosensing device. Gold nanoparticles, with an average diameter ~20 nm, were synthesized via the citrate reduction method and used to functionalize the glass core of an optical fiber. The sensing principle, which is based on localized surface plasmon resonance, requires the metal gold nanoparticles to be exposed to both the incident and absorbing lights, with the potential detection capabilities determined from the observed light intensity measurement. The optical fiber was uncladded at its center to expose the glass core fiber, and gold nanoparticles were immobilized on the exposed surface using a silane coupling agent. The sensitivity of the gold-nanoparticle-modified optical fibers in measuring the refractive index changes of a solution was compared for unclad lengths ranging between 1 and 2 cm. The attenuation of light depended on both the refractive index of solution and the length of the unclad fiber. The results showed that the fiber sensitivity increased as the unclad length increased due to greater amount of gold on the surface. Antibody-A, which has a specific binding to antigen-A, was then covalently linked to the fiber surface via an amide bond to demonstrate the potential bio-sensing platform of this sensor. The antibody-A functionalized optical fiber was used to detect the red blood cell samples in groups A, B, and O, where it effectively detected both the specific and non-specific binding signals. This fiber optic biosensor therefore provides a low-cost and simple fabrication setup that has potential field applications. Moreover, this setup could potentially be applied to detect other types of whole cell samples.en_US
dc.identifier.citationChiang Mai Journal of Science. Vol.45, No.5 (2018), 2168-2177en_US
dc.identifier.issn01252526en_US
dc.identifier.other2-s2.0-85056341088en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/45098
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85056341088&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.subjectMaterials Scienceen_US
dc.subjectMathematicsen_US
dc.subjectPhysics and Astronomyen_US
dc.titleGold-nanoparticle-based fiber optic sensor for sensing the refractive index of environmental solutionsen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85056341088&origin=inwarden_US

Files

Collections