Publication:
Multicentre dose audit for clinical trials of radiation therapy in Asia

dc.contributor.authorHideyuki Mizunoen_US
dc.contributor.authorShigekazu Fukudaen_US
dc.contributor.authorAkifumi Fukumuraen_US
dc.contributor.authorYuzuru Kutsutani Nakamuraen_US
dc.contributor.authorCao Jianpingen_US
dc.contributor.authorChul Koo Choen_US
dc.contributor.authorNana Suprianaen_US
dc.contributor.authorTo Anh Dungen_US
dc.contributor.authorMiriam Joy Calaguasen_US
dc.contributor.authorC. R.Beena Devien_US
dc.contributor.authorYaowalak Chansilpaen_US
dc.contributor.authorParvin Akhter Banuen_US
dc.contributor.authorMasooma Riazen_US
dc.contributor.authorSurya Esentayevaen_US
dc.contributor.authorShingo Katoen_US
dc.contributor.authorKumiko Karasawaen_US
dc.contributor.authorHirohiko Tsujiien_US
dc.contributor.otherNational Institute of Radiological Sciences Chibaen_US
dc.contributor.otherSoochow Universityen_US
dc.contributor.otherKorea Institute of Radiological and Medical Sciencesen_US
dc.contributor.otherUniversity of Indonesia, RSUPN Dr. Cipto Mangunkusumoen_US
dc.contributor.otherNational Cancer Hospitalen_US
dc.contributor.otherSt. Luke's Medical Center Quezon Cityen_US
dc.contributor.otherSarawak General Hospitalen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherDelta Hospital Ltden_US
dc.contributor.otherInstitute of Nuclear Medicine and Oncologyen_US
dc.contributor.otherKazakh Research Institute of Oncology and Radiologyen_US
dc.contributor.otherSaitama Medical Universityen_US
dc.contributor.otherTokyo Women's Medical University Hospitalen_US
dc.date.accessioned2018-12-21T07:46:27Z
dc.date.accessioned2019-03-14T08:03:44Z
dc.date.available2018-12-21T07:46:27Z
dc.date.available2019-03-14T08:03:44Z
dc.date.issued2017-05-01en_US
dc.description.abstract© The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. A dose audit of 16 facilities in 11 countries has been performed within the framework of the Forum for Nuclear Cooperation in Asia (FNCA) quality assurance program. The quality of radiation dosimetry varies because of the large variation in radiation therapy among the participating countries. One of the most important aspects of international multicentre clinical trials is uniformity of absolute dose between centres. The National Institute of Radiological Sciences (NIRS) in Japan has conducted a dose audit of participating countries since 2006 by using radiophotoluminescent glass dosimeters (RGDs). RGDs have been successfully applied to a domestic postal dose audit in Japan. The authors used the same audit system to perform a dose audit of the FNCA countries. The average and standard deviation of the relative deviation between the measured and intended dose among 46 beams was 0.4% and 1.5% (k = 1), respectively. This is an excellent level of uniformity for the multicountry data. However, of the 46 beams measured, a single beam exceeded the permitted tolerance level of ±5%. We investigated the cause for this and solved the problem. This event highlights the importance of external audits in radiation therapy.en_US
dc.identifier.citationJournal of Radiation Research. Vol.58, No.3 (2017), 372-377en_US
dc.identifier.doi10.1093/jrr/rrw108en_US
dc.identifier.issn13499157en_US
dc.identifier.issn04493060en_US
dc.identifier.other2-s2.0-85024883081en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/42704
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85024883081&origin=inwarden_US
dc.subjectEnvironmental Scienceen_US
dc.titleMulticentre dose audit for clinical trials of radiation therapy in Asiaen_US