Publication:
Anterior cruciate ligament tunnel position measurement reliability on 3-dimensional reconstructed computed tomography

dc.contributor.authorPisit Lertwanichen_US
dc.contributor.authorCesar A Q Martinsen_US
dc.contributor.authorShigehiro Asaien_US
dc.contributor.authorSheila J M Inghamen_US
dc.contributor.authorPatrick Smolinskien_US
dc.contributor.authorFreddie H. Fuen_US
dc.contributor.otherUniversity of Pittsburghen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-05-03T08:34:59Z
dc.date.available2018-05-03T08:34:59Z
dc.date.issued2011-03-01en_US
dc.description.abstractPurpose: The purpose of this study was to evaluate intraobserver and interobserver reliability of anterior cruciate ligament tunnel location measurement by use of 3-dimensional reconstructed computed tomography (CT). Methods: Three-dimensional reconstructed CT images of 31 cadaveric knees were used in this study. Twenty-one knees were operated on with a double-bundle technique, and ten knees were operated on with a single-bundle technique. Femoral tunnel location was measured with 3 methods on the medial-lateral view of the lateral femoral condyle in the strictly lateral position. Tibial tunnel location was measured in the top view of the proximal tibia. The images were evaluated independently by 2 orthopaedic surgeons. A second measurement was performed, by both testers, after a 4-week interval. Results: The 3 methods of femoral tunnel location measurement had intraobserver intraclass correlation coefficients (ICCs) that ranged from 0.963 to 0.998 and interobserver ICCs that ranged from 0.993 to 0.999. Tibial tunnel measurement had intraobserver ICCs that varied between 0.957 and 0.998 and interobserver ICCs that varied between 0.993 and 0.996. Conclusions: The measurement of the anterior cruciate ligament tunnel location on 3-dimensional reconstructed CT provided excellent intraobserver and interobserver reliability. Clinical Relevance: Three-dimensional reconstructed CT can be used for further studies to assess the effect of tunnel position on knee stability and patient outcomes. © 2011 Arthroscopy Association of North America.en_US
dc.identifier.citationArthroscopy - Journal of Arthroscopic and Related Surgery. Vol.27, No.3 (2011)en_US
dc.identifier.doi10.1016/j.arthro.2010.08.018en_US
dc.identifier.issn07498063en_US
dc.identifier.other2-s2.0-79952184081en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/12616
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79952184081&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleAnterior cruciate ligament tunnel position measurement reliability on 3-dimensional reconstructed computed tomographyen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79952184081&origin=inwarden_US

Files

Collections