Publication: Performance of the CRAFTi portable fluorometer comparing with the HPLC method for determining serum retinol
dc.contributor.author | Laksana Chaimongkol | en_US |
dc.contributor.author | Siwaporn Pinkaew | en_US |
dc.contributor.author | Harold C. Furr | en_US |
dc.contributor.author | John Estes | en_US |
dc.contributor.author | Neal E. Craft | en_US |
dc.contributor.author | Emorn Wasantwisut | en_US |
dc.contributor.author | Pattanee Winichagoon | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Prince of Songkla University | en_US |
dc.contributor.other | University of Wisconsin Madison | en_US |
dc.contributor.other | Craft Technologies | en_US |
dc.date.accessioned | 2018-05-03T08:01:15Z | |
dc.date.available | 2018-05-03T08:01:15Z | |
dc.date.issued | 2011-08-01 | en_US |
dc.description.abstract | Objective: To determine the performance of a portable fluorometer for measuring serum retinol (SR) concentration. Design and methods: Serum samples were obtained from 75 factory worker women and 143 school children. SR concentration was quantified using a portable fluorometer ('CRAFTi') and HPLC analysis. Results: SR by HPLC (1.23. ±. 0.43. μmol/L) and CRAFTi (1.16. ±. 0.46. μmol/L) was significantly correlated. Sensitivity and specificity were 85.3% and 78.0% (cutoff of 1.05. μmol/L). Kappa statistics showed moderate agreement. Conclusions: CRAFTi portable fluorometer is a promising field-friendly tool for screening vitamin A deficiency. © 2011 The Canadian Society of Clinical Chemists. | en_US |
dc.identifier.citation | Clinical Biochemistry. Vol.44, No.12 (2011), 1030-1032 | en_US |
dc.identifier.doi | 10.1016/j.clinbiochem.2011.05.023 | en_US |
dc.identifier.issn | 18732933 | en_US |
dc.identifier.issn | 00099120 | en_US |
dc.identifier.other | 2-s2.0-79960311327 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/11501 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79960311327&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.title | Performance of the CRAFTi portable fluorometer comparing with the HPLC method for determining serum retinol | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79960311327&origin=inward | en_US |