Publication:
Clinical evaluation of a simple image cytometer for CD4 enumeration on hiv-infected patients

dc.contributor.authorXiao Lien_US
dc.contributor.authorChristian Breukersen_US
dc.contributor.authorAurel Ymetien_US
dc.contributor.authorKovit Pattanapanyasaten_US
dc.contributor.authorKasama Sukapiromen_US
dc.contributor.authorLeon W M M Terstappenen_US
dc.contributor.authorJan Greveen_US
dc.contributor.otherUniversity of Twenteen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-09-24T08:48:18Z
dc.date.available2018-09-24T08:48:18Z
dc.date.issued2010-01-28en_US
dc.description.abstractBackground: Affordable, easy-to-use, and reliable CD4+ T lymphocyte enumeration systems are needed in resource-constrained settings to monitor HIV. Methods: A simple image cytometer was used to count fluorescently labeled CD4+ T and CD8+ T lymphocytes from CD3 immunomagnetically selected cells on blood specimens of 460 HIV-1-infected patients in Siriraj Hospital, Bangkok, Thailand. Results were compared with flow cytometry (FCM). Results: CD4+ T lymphocyte counts by image cytometer were comparable (R ≥ 0.97) with those by the FACSCount and the FACScan with a bias of 7.3 and 9.1%, respectively. At very low CD4+ T lymphocyte counts (≤50/μl) some over-count outliers were observed by the FACScan and image cytometer when compared with the FACSCount. For CD8 enumeration, the image cytometer showed a good correlation (R 5 0.96) and a consistent undercount (-17%) when compared with the FACSCount. Conclusions: Evaluation of the image cytometer for CD4 and CD8 enumeration demonstrated comparable results with FCM on a population of HIV-1-infected patients. The image cytometer is a good alternative method for point-of-care settings in resource-constrained countries. © 2009 Clinical Cytometry Society.en_US
dc.identifier.citationCytometry Part B - Clinical Cytometry. Vol.78, No.1 (2010), 31-36en_US
dc.identifier.doi10.1002/cyto.b.20488en_US
dc.identifier.issn15524957en_US
dc.identifier.issn15524949en_US
dc.identifier.other2-s2.0-74849123671en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/28799
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=74849123671&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectMedicineen_US
dc.titleClinical evaluation of a simple image cytometer for CD4 enumeration on hiv-infected patientsen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=74849123671&origin=inwarden_US

Files

Collections