Publication: Clinical evaluation of a simple image cytometer for CD4 enumeration on hiv-infected patients
dc.contributor.author | Xiao Li | en_US |
dc.contributor.author | Christian Breukers | en_US |
dc.contributor.author | Aurel Ymeti | en_US |
dc.contributor.author | Kovit Pattanapanyasat | en_US |
dc.contributor.author | Kasama Sukapirom | en_US |
dc.contributor.author | Leon W M M Terstappen | en_US |
dc.contributor.author | Jan Greve | en_US |
dc.contributor.other | University of Twente | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.date.accessioned | 2018-09-24T08:48:18Z | |
dc.date.available | 2018-09-24T08:48:18Z | |
dc.date.issued | 2010-01-28 | en_US |
dc.description.abstract | Background: Affordable, easy-to-use, and reliable CD4+ T lymphocyte enumeration systems are needed in resource-constrained settings to monitor HIV. Methods: A simple image cytometer was used to count fluorescently labeled CD4+ T and CD8+ T lymphocytes from CD3 immunomagnetically selected cells on blood specimens of 460 HIV-1-infected patients in Siriraj Hospital, Bangkok, Thailand. Results were compared with flow cytometry (FCM). Results: CD4+ T lymphocyte counts by image cytometer were comparable (R ≥ 0.97) with those by the FACSCount and the FACScan with a bias of 7.3 and 9.1%, respectively. At very low CD4+ T lymphocyte counts (≤50/μl) some over-count outliers were observed by the FACScan and image cytometer when compared with the FACSCount. For CD8 enumeration, the image cytometer showed a good correlation (R 5 0.96) and a consistent undercount (-17%) when compared with the FACSCount. Conclusions: Evaluation of the image cytometer for CD4 and CD8 enumeration demonstrated comparable results with FCM on a population of HIV-1-infected patients. The image cytometer is a good alternative method for point-of-care settings in resource-constrained countries. © 2009 Clinical Cytometry Society. | en_US |
dc.identifier.citation | Cytometry Part B - Clinical Cytometry. Vol.78, No.1 (2010), 31-36 | en_US |
dc.identifier.doi | 10.1002/cyto.b.20488 | en_US |
dc.identifier.issn | 15524957 | en_US |
dc.identifier.issn | 15524949 | en_US |
dc.identifier.other | 2-s2.0-74849123671 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/28799 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=74849123671&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Medicine | en_US |
dc.title | Clinical evaluation of a simple image cytometer for CD4 enumeration on hiv-infected patients | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=74849123671&origin=inward | en_US |