Publication: Does shortened application time affect long-term bond strength of universal adhesives to dentin?
Issued Date
2018-09-01
Resource Type
ISSN
03617734
DOI
Other identifier(s)
2-s2.0-85052882756
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Bibliographic Citation
Operative Dentistry. Vol.43, No.5 (2018), 549-558
Suggested Citation
P. Saikaew, M. Matsumoto, A. F.M.A. Chowdhury, R. M. Carvalho, H. Sano Does shortened application time affect long-term bond strength of universal adhesives to dentin?. Operative Dentistry. Vol.43, No.5 (2018), 549-558. doi:10.2341/17-205-L Retrieved from: https://repository.li.mahidol.ac.th/handle/20.500.14594/45700
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
Does shortened application time affect long-term bond strength of universal adhesives to dentin?
Other Contributor(s)
Abstract
© 2018 Indiana University School of Dentistry. All rights reserved. Objective: This study evaluated the effect of shortened application time on long-term bond strength with universal adhesives. Methods and Materials: Three universal adhesives were used: Clearfil Universal Bond (CU, Kuraray Noritake Dental Inc, Tokyo, Japan), Scotchbond Universal Adhesive (SB, 3M ESPE, St Paul, MN, USA) or G-Premio Bond (GP, GC Corp, Tokyo, Japan). Sixty molars were cut to expose midcoronal dentin and prepared with a regular diamond bur. Each adhesive was applied either according to the manufacturer's instruction or with shortened time. Specimens were stored in distilled water at 378C for 24 hours and then cut into resin-dentin sticks. Microtensile bond strength (lTBS) was tested after either 24 hours or 1 year of water storage. Data were analyzed by the three-way ANOVA and Duncan tests (a=0.05). Fracture modes were analyzed under a scanning electron microscope (SEM). One dentin stick per group was selected after fracture mode analysis and further observed using transmission electron microscopy (TEM). Six additional dentin discs were prepared and conditioned with each adhesive under the different application time to observe the adhesive-smear layer interaction by SEM. Results: Shortened application time affected the lTBS (p,0.001) while storage time did not affect bond strength (p=0.187). A significant effect of shortened application time on lTBS was observed in the CU at 1 year and in the GP at both storage times. Conclusions: One-year storage time had no effect on the lTBS of universal adhesives to bur-cut dentin. The performance of universal adhesives can be compromised when applied using a shortened application time.