Publication: A flow system for the determination of metal speciation in soil by sequential extraction
dc.contributor.author | J. Shiowatana | en_US |
dc.contributor.author | N. Tantidanai | en_US |
dc.contributor.author | S. Nookabkaew | en_US |
dc.contributor.author | D. Nacapricha | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | The Institute of Science and Technology for Research and Development, Mahidol University | en_US |
dc.date.accessioned | 2018-09-07T09:40:51Z | |
dc.date.available | 2018-09-07T09:40:51Z | |
dc.date.issued | 2001-01-01 | en_US |
dc.description.abstract | A flow extraction system with on-line and off-line flame atomic absorption spectrometric (FAAS) detection was developed to speed up, facilitate, and improve the accuracy of sequential extraction for metal speciation in solid materials. A flow extraction system with off-line detection was more advantageous than the on-line detection. In the proposed system, extraction was performed in a closed extraction chamber where extractants were flowing through sequentially. The extract from each extraction was collected in 4-10 fractions to obtain a total of approximately 180 ml for subsequent FAAS determination. The system is simple, easy to construct and operate. It has less risk of contamination and human error. A widely used three-step sequential extraction scheme was used to evaluate the novel system by analyzing Ca, Fe, Mn, Cu, and Zn in a certified reference material. The extraction time for three-step sequential extraction of soil sample was 4 h. The analytical results for Ca, Fe, Mn, Cu, and Zn of a soil certified reference material using the proposed system were compared with those of the conventional batch extraction. © 2001 Elsevier Science Ltd. All rights reserved. | en_US |
dc.identifier.citation | Environment International. Vol.26, No.5-6 (2001), 381-387 | en_US |
dc.identifier.doi | 10.1016/S0160-4120(01)00016-2 | en_US |
dc.identifier.issn | 18736750 | en_US |
dc.identifier.issn | 01604120 | en_US |
dc.identifier.other | 2-s2.0-0035000076 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/26543 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0035000076&origin=inward | en_US |
dc.subject | Environmental Science | en_US |
dc.title | A flow system for the determination of metal speciation in soil by sequential extraction | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0035000076&origin=inward | en_US |