Publication: Evaluation of five commercial assays for the detection of Anti-dsDNA antibodies: Three crithidia luciliae indirect immunofluorescence test kits and two enzyme immunoassay kits
Issued Date
2014-01-01
Resource Type
ISSN
01252208
Other identifier(s)
2-s2.0-84900819386
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Bibliographic Citation
Journal of the Medical Association of Thailand. Vol.97, No.2 (2014), 220-224
Suggested Citation
Ronnachai Viriyataveekul, Jaruda Kobkitjaroen, Jintana Jaiyen, Siriporn Kongkriengdach, Sumalee Potprasart Evaluation of five commercial assays for the detection of Anti-dsDNA antibodies: Three crithidia luciliae indirect immunofluorescence test kits and two enzyme immunoassay kits. Journal of the Medical Association of Thailand. Vol.97, No.2 (2014), 220-224. Retrieved from: https://repository.li.mahidol.ac.th/handle/20.500.14594/34510
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
Evaluation of five commercial assays for the detection of Anti-dsDNA antibodies: Three crithidia luciliae indirect immunofluorescence test kits and two enzyme immunoassay kits
Other Contributor(s)
Abstract
Objective: There are various methods for anti-dsDNA detection. Crithidia luciliae indirect immunofluorescence test (CLIFT) and enzyme immunoassay (EIA) are the most commonly used at present. A number of CLIFT and EIA kits are commercially available. The objective of the present study was to evaluate the diagnostic performance of three commercial CLIFT kits, two commercial EIA kits, and their combinations for anti-dsDNA detection. Material and Method: One hundred thirty nine sera sent for anti-dsDNA testing were investigated. Three commercial CLIFT kits (kit C1, C2, and C3) and two commercial EIA kits (kit E1 and E2) were evaluated. Sensitivities and specificities were calculated. The gold standard methods were the consensus results of all five kits, together with the clinical diagnosis when the results of five kits were discrepant. Results: Of 139 sera investigated, 94 (67.6%) sera showed concordant results for all five kits and 45 (32.4%) sera showed discordant results. Thirty-five of those 45 patients (77.7%) were diagnosed as SLE. Sensitivities and specificities of the kits were as follows, C1 82.1% and 94%, C2 46.4% and 100%, C3 78.6% and 98.8%, E1 71.4% and 94%, and E2 75% and 93.8%, respectively. Kit C3 yielded the maximum sum of sensitivity and specificity (177.4%). Sensitivities and specificities of the combinations of CLIFT and EIA kits were as follows, C1 + E1 89.3% and 90.4%, C1 + E2 98.2% and 87.9%, C2 + E1 73.2% and 94%, C2 + E2 82.1% and 92.8%, C3 + E1 85.7% and 94%, and C3 + E2 94.6% and 91.6%, respectively. The combination of kit C3 and E2 yielded the maximum sum of sensitivity and specificity (186.2%). Conclusion: Kit C3 was the assay of choice for anti-dsDNA detection. EIA kits yielded lower sensitivities and specificities than two of three CLIFT kits. Therefore, they should not be used as the first assay for anti-dsDNA screening. When CLIFT and EIA assays were combined, sensitivities were increased. Kit E2 helped CLIFT kits to detect more SLE cases than E1.