Publication:
A "dual-acceptor channel" membraneless gas-diffusion unit for simultaneous determination of ethanol and acetaldehyde in liquors using reverse flow injection

dc.contributor.authorNathawut Choengchanen_US
dc.contributor.authorBangerdsuk Poontongen_US
dc.contributor.authorArjnarong Mathaweesansurnen_US
dc.contributor.authorNoppadol Maneeraten_US
dc.contributor.authorShoji Motomizuen_US
dc.contributor.authorNuanlaor Ratanawimarnwongen_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.otherOkayama Universityen_US
dc.contributor.otherKing Mongkut's Institute of Technology Ladkrabangen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherSrinakharinwirot Universityen_US
dc.contributor.otherFlow Innovation-Research for Science and Technology Laboratories (FIRST Labs.en_US
dc.date.accessioned2019-08-23T10:52:45Z
dc.date.available2019-08-23T10:52:45Z
dc.date.issued2018-01-01en_US
dc.description.abstract© The Japan Society for Analytical Chemistry. A new design of membraneless gas-diffusion unit with dual acceptor channels for separation, collection and simultaneous determination of two volatile analytes in liquid sample is presented. The unit is comprised of three parallel channels in a closed module. A sample is aspirated into the central channel and two kinds of reagents are introduced into the other two channels. Two analytes are isolated from the sample matrix by diffusion into head-space and absorbed into the specific reagents. Non-absorbed vapor is released by opening the programmable controlled lid. The unit was applied to liquors for measurement of ethanol and acetaldehyde using reverse flow injection. Dichromate and nitroprusside were exploited as reagents for colorimetric detection of ethanol and acetaldehyde, respectively. Good linearity ranges (r2 > 0.99) with high precision (RSD < 2%) and high accuracy (recovery: 90 - 105%) were achieved. The results were compared to the results by GC-FID and no significant difference was observed by paired t-test (95% confidence).en_US
dc.identifier.citationAnalytical Sciences. Vol.34, No.2 (2018), 169-175en_US
dc.identifier.doi10.2116/analsci.34.169en_US
dc.identifier.issn13482246en_US
dc.identifier.issn09106340en_US
dc.identifier.other2-s2.0-85041825200en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/45526
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85041825200&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleA "dual-acceptor channel" membraneless gas-diffusion unit for simultaneous determination of ethanol and acetaldehyde in liquors using reverse flow injectionen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85041825200&origin=inwarden_US

Files

Collections