Publication:
Repeatability in column preparation of a reversed-phase C18 monolith and its application to separation of tocopherol homologues

dc.contributor.authorSirichai Kositaraten_US
dc.contributor.authorNorman William Smithen_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.authorPrapin Wilairaten_US
dc.contributor.authorPatcharin Chaisuwanen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherKing's College Londonen_US
dc.contributor.otherSrinakharinwirot Universityen_US
dc.date.accessioned2018-05-03T08:07:23Z
dc.date.available2018-05-03T08:07:23Z
dc.date.issued2011-06-15en_US
dc.description.abstractThis work investigated the repeatability of column preparation for a reversed-phase C18 monolith, namely stearyl methacrylate-co-ethylene glycol dimethacrylate (SMA-EDMA). The columns were thermally polymerised using three commonly available heating devices (GC oven, hot air oven and water bath) and their chromatographic performance evaluated using micro-liquid chromatography for separation of five test compounds. Precision in terms of %RSD of retention times were 9.0, 6.5, and 12.5 using GC oven, hot air oven and water bath, respectively. Between-batch precision for the hot air oven (n = 3 days) was less than 10.4% for retention time. The SMA-EDMA monolith was applied to the separation of tocopherol homologues by capillary electrochromatography. Usually tocopherol homologues cannot be completely separated by conventional reversed-phase C8- or C18-packed bed or C18-silica based monolithic columns. Polymer monolith has been shown to give remarkable selectivity towards the tocopherols compared to the conventional microparticulate phase and silica based monolith. Successful separation of the tocopherol isomers was achieved on the SMA-EDMA monolith without any column modification. © 2011 Elsevier B.V. All rights reserved.en_US
dc.identifier.citationTalanta. Vol.84, No.5 (2011), 1374-1378en_US
dc.identifier.doi10.1016/j.talanta.2011.03.083en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-79958106019en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/11713
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79958106019&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleRepeatability in column preparation of a reversed-phase C18 monolith and its application to separation of tocopherol homologuesen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79958106019&origin=inwarden_US

Files

Collections