Publication:
Source-identifying biomarker ions between environmental and clinical Burkholderia pseudomallei using whole-cell Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS)

dc.contributor.authorSuthamat Niyompanichen_US
dc.contributor.authorJanthima Jaresitthikunchaien_US
dc.contributor.authorKitima Srisangaen_US
dc.contributor.authorSittiruk Roytrakulen_US
dc.contributor.authorSumalee Tungpradabkulen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherThailand National Center for Genetic Engineering and Biotechnologyen_US
dc.date.accessioned2018-11-09T01:44:29Z
dc.date.available2018-11-09T01:44:29Z
dc.date.issued2014-06-10en_US
dc.description.abstractBurkholderia pseudomallei is the causative agent of melioidosis, which is an endemic disease in Northeast Thailand and Northern Australia. Environmental reservoirs, including wet soils and muddy water, serve as the major sources for contributing bacterial infection to both humans and animals. The whole-cell matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (whole-cell MALDI-TOF MS) has recently been applied as a rapid, accurate, and high-throughput tool for clinical diagnosis and microbiological research. In this present study, we employed a whole-cell MALDI-TOF MS approach for assessing its potency in clustering a total of 11 different B. pseudomallei isolates (consisting of 5 environmental and 6 clinical isolates) with respect to their origins and to further investigate the source-identifying biomarker ions belonging to each bacterial group. The cluster analysis demonstrated that six out of eleven isolates were grouped correctly to their sources. Our results revealed a total of ten source-identifying biomarker ions, which exhibited statistically significant differences in peak intensity between average environmental and clinical mass spectra using ClinProTools software. Six out of ten mass ions were assigned as environmental-identifying biomarker ions (EIBIs), including, m/z 4,056, 4,214, 5,814, 7,545, 7,895, and 8,112, whereas the remaining four mass ions were defined as clinical-identifying biomarker ions (CIBIs) consisting of m/z 3,658, 6,322, 7,035, and 7,984. Hence, our findings represented, for the first time, the source-specific biomarkers of environmental and clinical B. pseudomallei. © 2014 Niyompanich et al.en_US
dc.identifier.citationPLoS ONE. Vol.9, No.6 (2014)en_US
dc.identifier.doi10.1371/journal.pone.0099160en_US
dc.identifier.issn19326203en_US
dc.identifier.other2-s2.0-84902590136en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/33009
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84902590136&origin=inwarden_US
dc.subjectAgricultural and Biological Sciencesen_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectMedicineen_US
dc.titleSource-identifying biomarker ions between environmental and clinical Burkholderia pseudomallei using whole-cell Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS)en_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84902590136&origin=inwarden_US

Files

Collections